Login

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download

Register

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to content on this page

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download

Thank you for your interest

You now have access to K3HB-X

A confirmation email has been sent to

Continue to page

Please or get direct access to download this document

K3HB-X

K3HB-X

Process indicator ideal for discriminating and displaying measurements

These indicators with analogue input feature a clear and easy-to-use colour-change display. All models are equipped with an IP66 housing. K3HB series is high speed, with a sample rate of 50Hz.

  • Position meter indication for easy monitoring
  • Optional DeviceNet, RS-232C, RS-485
  • Double display, with 5 digits, in two colours
  • Dimensions: H 48 x W 96 x D 100mm

Specifications & ordering info

Ordering information

Type of indicator

Input sensor type and range

Supply voltage

Order code

Process indicator
K3HB-X

AC current input, from 0.000 to 10.000 A, 0.0000 to 19.999 mA

100 to 240 VAC

K3HB-XAA 100-240VAC

24 VAC/VDC

K3HB-XAA 24VAC/VDC

DC current input, from ±199.99 mA, to 4.000 to 20.000 mA

100 to 240 VAC

K3HB-XAD 100-240VAC

24 VAC/VDC

K3HB-XAD 24VAC/VDC

AC voltage input, from 0.0 to 400.0 V to 0.0000 to 1.999 V1

100 to 240 VAC

K3HB-XVA 100-240VAC

DC voltage input, from ±199.99 V to 1.0000 to 5.0000 V

100 to 240 VAC

K3HB-XVD 100-240VAC

24 VAC/VDC

K3HB-XVD 24VAC/VDC

Temperature indicator
K3HB-H

Temperature input Pt100, thermocouple K, J, T, E, L, U, N, R, S, B, W

100 to 240 VAC

K3HB-HTA 100-240VAC

24 VAC/VDC

K3HB-HTA 24VAC/VDC

Weighing indicator
K3HB-V

Load cell input (DC low voltage input), 0.00 to 199.99 mV, 0.000 to 19.999 mV,
100.00 mV, 199.999 mV

100 to 240 VAC

K3HB-VLC 100-240 VAC

24 VAC/VDC

K3HB-VLC 24VAC/VDC

Linear sensor indicator
K3HB-S

DC process input, 0 to 5 V, 1 to 5 V, −5 to 5 V, −10 to 10 V, 0 to 20 mA, 4 to 20 mA

24 VAC/VDC

K3HB-SSD AC/DC24

100 to 240 VAC

K3HB-SSD AC100-240

Option boards

Sensor power supply/output boards

Slot

Output

Sensor power supply

Communications

Applicable indicator types

Order code

B

Relay

PASS: SPDT

12 VDC ±10%, 80 mA

K3HB-X, -H, -S

K33-CPA2

Linear current

DC0(4) - 20 mA

K3HB-X, -H, -S

K33-L1 A3

Linear voltage

DC0(1) - 5 V, 0 to 10 V

K3HB-X, -H, -S

K33-L2A2

K3HB-X, -H, -S

K33-A2

RS-232C

K3HB-X, -H, -S

K33-FLK1 A2

RS-485

K3HB-X, -H, -S

K33-FLK3A2

Relay

PASS: SPDT

10 VDC ±5%, 100 mA

K3HB-V

K33-CPB1

Linear current

DC0(4) - 20 mA

K3HB-V

K33-L1B2

Linear voltage

DC0(1) - 5 V, 0 to 10 V

K3HB-V

K33-L2B2

K3HB-V

K33-B2

RS-232C

K3HB-V

K33-FLK1B2

RS-485

K3HB-V

K33-FLK3B2

Relay/transistor output boards

Slot

Output

Communications

Order code

C

Relay

H/L: SPDT each

K34-C1

HH/H/LL/L: SPST-NO each

K34-C2

Transistor

NPN open collector: HH/H/PASS/L/LL

K34-T1

PNP open collector: HH/H/PASS/L/LL

K34-T2

DeviceNet

K34-DRT4

Event input boards

Slot

Input type

Number of points

Communications

Order code 5

D

NPN open collector

5

M3 terminal blocks

K35-1

PNP open collector

5

M3 terminal blocks

K35-3

Note: K32-DICN special cable accessory (for event inputs with 8-pin connector) available on request. Please contact your Omron representative.

Specifications

Power supply voltage

100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC

Allowable power supply voltage range

85 to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC

Power consumption

100 to 240 V: 18 VA max. (max. load), 24 VAC/DC: 11 VA/7 W max. (max. load)

Display method

Negative LCD (backlit LED) display 7-segment digital display
(character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green))

Ambient operating temperature

−10 to 55°C (with no icing or condensation)

Display range

−19,999 to 99,999

Weight

Approx. 300 g (base unit only)

Degree of protection

Front-panel

Conforms to NEMA 4X for indoor use (equivalent to IP66)

Rear case

IP20

Terminals

IP00 + finger protection (VDE0106/100)

Memory protection

EEPROM (non-volatile memory), number of rewrites: 100,000

Event input ratings

Contact

ON: 1 kΩ max., OFF: 100 kΩ min.

No-contact

ON residual voltage: 2 V max., OFF leakage current: 0.1 mA max., load current: 4 mA max.
Maximum applied voltage: 30 VDC max.

Output ratings

Transistor output

Maximum load voltage

24 VDC

Maximum load current

50 mA

Leakage current

100 µA max.

Contact output
(resistive load)

Rated load

5 A at 250 VAC, 5 A at 30 VDC

Rated through current

5 A

Mechanical life expectancy

5,000,000 operations

Electrical life expectancy

100,000 operations

Linear output

Allowable load impedance

500 Ω max. (mA); 5 kΩ min. (V)

Resolution

Approx. 10,000

Output error

±0.5% FS

Size in mm (H×W×D)

48×96×100


1. There are other models available on request. Please contact your Omron representative for special request.
2. CPA/CPB can be combined with relay outputs only.
3. Only one of the following can be used by each digital indicator: RS-232C/RS-485 communications, a linear output, or DeviceNet communications.
K3HB has got three slots for option boards: Slot B, slot C and slot D.
4. Only one of the following can be used by each digital indicator: RS-232C/RS-485 communications, a linear output, or DeviceNet communications.
K3HB has got three slots for option boards: Slot B, slot C and slot D.
5. There are other models available on request. Please contact your Omron representative for special request.
1. There are other models available on request. Please contact your Omron representative for special request.
2. CPA/CPB can be combined with relay outputs only.
3. Only one of the following can be used by each digital indicator: RS-232C/RS-485 communications, a linear output, or DeviceNet communications.
K3HB has got three slots for option boards: Slot B, slot C and slot D.
4. Only one of the following can be used by each digital indicator: RS-232C/RS-485 communications, a linear output, or DeviceNet communications.
K3HB has got three slots for option boards: Slot B, slot C and slot D.
5. There are other models available on request. Please contact your Omron representative for special request.

How can we help you?

If you have a question or would like to ask for a quote, please contact us or send a request.

+46 (8) 632 35 00
Contact us

Kontakta mig K3HB-X

k3hb-x prod

Vänligen fyll i alla fält markerade med *. Dina personliga uppgifter behandlas konfidentiellt.

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Text area error notification

Checkbox error notification

Checkbox error notification

Tack för din förfrågan. Vi återkommer inom kort.

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download
+46 (8) 632 35 00
+46 (8) 632 35 00
Request quotation
Request quotation

Offert för K3HB-X

Fyll i alla obligatoriska fält. Vänligen fyll i alla fält markerade med *. Dina personliga uppgifter behandlas konfidentiellt.

k3hb-x prod

Personliga detaljer

K3HB-X

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Offertinformation

Select notification error

Select notification error

Text area error notification

Checkbox error notification

Checkbox error notification

Tack för din offertförfrågan. Vi återkommer med önskad information inom kort.

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download
Request quotation
Request quotation

Features

Harsh environment

Control products can be subjected to harsh environments where they can be splashed during the process or covered in dust or get warm through their location. The E5CN, E5CSV, H7CX, H5CX and K3HB all feature a NEMA4X (IP66 equivalent) front panels so are suitable for the use in these applications, also the low profile fascia means that they are less prominent in the front of the panel and so less likely to become dirty.

Monitoring concentration

Monitoring the flow rate of the two liquids means that if one changes the other will match the change, with the offset required helping to maintain product quality. The colour change display can be used to identify when the rate changes and additional alarm points can be set to give local or remote outputs. A linear output could be used for an input into a PLC system, SCADA or chart recorder if external monitoring or traceability are required.

Monitoring flow rate

A linear output flow sensor is used in the pipe to measure the flowrate through the tube, the K3HB-X is used as a local display. This can be the first indication of potential problems within the system, a leak would cause the flow rate to increase as the liquid is lost a blockage would cause a decrease in flow rate.