D6FZ-FGS-serien
Identify waste in your compressed air lines
Measure air leakage, use and pressure to improve energy management at the air line. The D6FZ-FGS1000 series of air flow sensors provide visualization of invisibile energy waste for compressed air systems to improve Energy Manager and Energy Service company (ESCO) actions.
- High accuracy flow measurement
- Simultaneous leakage, usage, pressure and temperature measurement with one unique product
- 2 Analogue and 2 pulse outputs
- RS485 communications
- High degree of protection: IP64
- Mountable to curved pipe or coupler
- Operation indicator
- Threshold value (peak/bottom/leak)
- Alarm hold
Specifications & ordering info
Ordering information
Units
![]() |
||
![]() |
||
![]() |
||
![]() |
||
![]() |
Accessories (sold separately)
![]() |
||||
![]() |
||||
![]() |
||||
![]() |
||||
![]() |
||||
Specifications
Air flow sensor
Air, nitrogen (N2)1 |
||||
Measurement range2 |
||||
Accuracy2 |
||||
Momentary flow/integrated flow/reversing display/zero point adjustment/peak and bottom hold/key lock/eco model/scaling (analog output)/judgement hysteresis/teaching |
||||
Current output 4 to 20 mA (1 contact), maximum load resistance 300 Ω max. |
||||
Open collector output (2 outputs) 26.4 VDC 50 mA max. (Outputs can be selected from judgement output, pulse output and unit error output) |
||||
2-wire half duplex communication, start-stop synchronized method Baud rate: 9.6k/19.2k/38.4k/115.2kbps, data bit length: 7/8bit, stop bit length: 1/2bit, parity: none/even/odd, |
||||
Momentary flow, integrated flow, judgement output, unit error output |
||||
Direct piping:10 kPa max. (0.5 MPa, at maximum flow) |
|||
16 to 24 VDC ±10% ripple (p-p) 10% max. (Using single unit), |
|||
Current output 4 to 20 mA (2 contact)3 Max. load resistance 270 Ω max. |
|||
Open drain output (2 outputs)4 24 VDC 50mA max. ON residual voltage 1.5 V max., OFF leakage current 50 µA max. |
|||
2-wire half duplex communication, start-stop synchronized method Baud rate: 115.2 kbps (fixed), Data bit length: 8 bits (fixed), stop bit length: 1 bit (fixed), parity: even (fixed), communications protocol: compatible with CompoWay/F |
|||
Momentary standard flow, integrated standard flow, pressure, unit error output |
|||
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Kontakta mig D6FZ-FGS-serien

Tack för din förfrågan. Vi återkommer inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
DownloadOffert för D6FZ-FGS-serien
Fyll i alla obligatoriska fält. Vänligen fyll i alla fält markerade med *. Dina personliga uppgifter behandlas konfidentiellt.

Tack för din offertförfrågan. Vi återkommer med önskad information inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
Download