Kontaktsensorer
E9NC-T Contact Type Smart Sensor
Advanced, Durable, Space-saving Contact Sensors.
- OMRON’s unique ball spline mechanism for resistance to vibration and shock.
- Employs a robot cable that withstands bending.*1
- Slim, short Sensor Heads and slim Amplifier Units to save you space.
- A flanged type that does not require mounting brackets and is easy to replace.
- Transmits high-precision data with a resolution of 0.1 μm across a network (E9NC-TA0 only).
Specifications & ordering info
Ordering Information
Sensor Heads
(Connection Cable between Preamplifier and Amplifier Unit is not provided with the Sensor Head. Be sure to have the Connection Cable ready when using the Sensor.)
Type | Appearance | Measuring range (Moving range) |
Resolution | Order code |
---|---|---|---|---|
Straight type | 5 mm | 0.1 μm | E9NC-TH5S 2M | |
Right-angle air type | E9NC-TH5L 2M | |||
Flanged type/Straight type | E9NC-TH5SF 2M | |||
Flanged type/Right-angle air type | E9NC-TH5LF 2M | |||
Straight type | 12 mm | E9NC-TH12S 2M | ||
Right-angle air type | E9NC-TH12L 2M | |||
Flanged type/Straight type | E9NC-TH12SF 2M | |||
Flanged type/Right-angle air type | E9NC-TH12LF 2M |
Amplifier Units
Type | Appearance | Order code |
---|---|---|
Communications
2
A Sensor Communications Unit
is required if you want to use the Amplifier Unit on a network. |
E9NC-TA0 |
Type | Appearance | Order code | |
---|---|---|---|
NPN output | PNP output | ||
ON/OFF output | E9NC-TA21 2M | E9NC-TA51 2M |
Connection Cable between Preamplifier and Amplifier Unit
Cable length | Quantity | Order code |
---|---|---|
0.5 m | 1 | E9NC-TXC05 |
5 m | 1 | E9NC-TXC5 |
10 m | 1 | E9NC-TXC10 |
20 m | 1 | E9NC-TXC20 |
Accessories (Sold Separately)
Sensor Head Accessories
Probe
The E9NC-TB1 is provided with the Sensor Head. Order replacements as required.
Type | Appearance | Quantity | Order code |
---|---|---|---|
3-dia. probe | 1 | E9NC-TB1 | |
Nylon probe | 1 | E9NC-TB2 | |
Probe for flat surfaces | 1 | E9NC-TB3 |
Rubber boots
A rubber boot is provided with the Sensor Head. Order replacements as required.
Applicable Sensor Head | Quantity | Order code |
---|---|---|
E9NC-TH5 |
1 | E9NC-G5 |
E9NC-TH12 |
1 | E9NC-G12 |
Amplifier Unit Accessories
Amplifier Unit Mounting Bracket
A Mounting Bracket is not provided with the Amplifier Unit. It must be ordered separately as required.
Appearance | Quantity | Order code |
---|---|---|
1 | E39-L143 |
DIN Track
A DIN Track is not provided with the Amplifier Unit. It must be ordered separately as required.
Appearance | Type | Quantity | Order code |
---|---|---|---|
Shallow type, total length: 1 m | 1 | PFP-100N | |
Shallow type, total length: 0.5 m | 1 | PFP-50N | |
Deep type, total length: 1 m | 1 | PFP-100N2 |
End Plate
An End Plate is not provided with the Amplifier Unit. It must be ordered separately as required.
Appearance | Quantity | Order code |
---|---|---|
1 | PFP-M |
Cover
Attach these Covers to Amplifier Units. Order a Cover when required, e.g., if you lose the covers.
Appearance | Quantity | Order code |
---|---|---|
1 | E39-G22 FOR E9NC-TA |
Related Products
Sensor Communications Units
Type | Appearance | Order code |
---|---|---|
Sensor Communications Unit for EtherCAT |
E3NW-ECT | |
Sensor Communications Unit for CC-Link | E3NW-CCL | |
Distributed Sensor Unit
2
The Distributed
Sensor Unit can be connected to any of the Sensor Communications
Units. |
E3NW-DS |
Refer to your OMRON website for details.
The E9NC-TA0 is supported for firmware version 1.03 or higher (Sensor Communications Units manufactured in July 2014 or later).
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
CC-Link is a registered trademark of Mitsubishi Electric Corporation. The trademark is managed by the CC-Link Partner Association.
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Kontakta mig Kontaktsensorer
Tack för din förfrågan. Vi återkommer inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
DownloadOffert för Kontaktsensorer
Fyll i alla obligatoriska fält. Vänligen fyll i alla fält markerade med *. Dina personliga uppgifter behandlas konfidentiellt.
Tack för din offertförfrågan. Vi återkommer med önskad information inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
DownloadFeatures
Durable
Handles measurement applications in harsh environments. Tough under vibration and shock (due to ball spline mechanism), water resistant (Magnetic Sensing Method) and withstands bending of robot cables.
Space-saving
Handles measurement applications with limited space with the help of slim, short sensor heads (8mm outside diameter) and slim amplifier units (only 10mm wide).
Advanced
Handles advances measurement applications. Data communications & high precision data transmission carried out via field networks (0.1-μm resolution). Can connect up to 30 sensors with reduced wiring, and holds eight calculation functions including maximum value, minimum value, flatness, average, step, twist, warp and thickness.