Safety Switches
Filter by
D4SL-N | D41G | D4NL | D41L | F3S-TGR-KHL_ | D4N | D4N-_R | D4B-_N | D4F | D4NH | D4NS | D4GS | F3S-TGR-KM/KH | D4BS | F3S-TGR-N_R | F3S-TGR-N_X | D40A | D40Z | F3S-TGR-N_C | F3S-TGR-N_M/-N_U | D41D | F3S-TGR-S_A/-S_D | D40ML | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Guard Monitoring and locking | Guard Monitoring and locking | Guard Monitoring and locking | Guard Monitoring and locking | Guard Monitoring and locking | Limiting and Positioning | Limiting and Positioning | Limiting and Positioning | Limiting and Positioning | Limiting and Positioning | Guard Monitoring | Guard Monitoring | Guard Monitoring | Guard Monitoring | Guard Monitoring | Guard Monitoring | Guard Monitoring | Guard Monitoring | Guard Monitoring | Guard Monitoring | Guard Monitoring | Guard Monitoring | Guard Monitoring and locking | |
2 | 2 4 | 2 | 2 4 | 2 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 3 | 3 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | |
Low | High | Low | High | Low | Low | Low | Low | Low | Low | Low | Low | Low | Low | Low | Low | Low | Low | Low | High | High | Low | High | |
Physical contact, force, pressure | Physical contact, force, pressure | Physical contact, force, pressure | Physical contact, force, pressure | Physical contact, force, pressure | Physical contact, force, pressure | Physical contact, force, pressure | Physical contact, force, pressure | Physical contact, force, pressure | Physical contact, force, pressure | Physical contact, force, pressure | Physical contact, force, pressure | Physical contact, force, pressure | Physical contact, force, pressure | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | |
Tongue | Tongue Coded RFID tag | Tongue | Coded RFID tag Star handle | Tongue | Lever | Lever | Lever | Lever | Hinge | Tongue | Tongue | Tongue | Tongue | Uncoded magnet | Uncoded magnet | Coded magnet | Coded magnet | Coded magnet | Coded RFID tag | Coded RFID tag | Coded magnet | Coded RFID tag | |
Yes | Yes | Yes | Yes | Yes | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | Yes | |
No | No | No | Yes | Yes | No | No | No | No | No | No | No | Yes | No | Yes | Yes | No | No | Yes | No | No | Yes | Yes | |
Plastic | Plastic | Plastic | Plastic | Stainless-steel | Plastic | Plastic | Metal | Metal | Plastic | Plastic | Plastic | Plastic Metal | Metal | Plastic Stainless-steel | Plastic Stainless-steel | Plastic | Plastic | Plastic Stainless-steel | Plastic | Plastic | Plastic Stainless-steel | Plastic Metal | |
Potential free contact | PNP | Potential free contact | PNP | Potential free contact | Potential free contact | Potential free contact | Potential free contact | Potential free contact | Potential free contact | Potential free contact | Potential free contact | Potential free contact | Potential free contact | Reed contact | Reed contact | PNP | PNP | PNP | PNP | PNP | Dual relay | PNP | |
D4SL-N | D41G | D4NL | D41L | F3S-TGR-KHL_ | D4N | D4N-_R | D4B-_N | D4F | D4NH | D4NS | D4GS | F3S-TGR-KM/KH | D4BS | F3S-TGR-N_R | F3S-TGR-N_X | D40A | D40Z | F3S-TGR-N_C | F3S-TGR-N_M/-N_U | D41D | F3S-TGR-S_A/-S_D | D40ML |
-
D4SL-N
Guard-lock safety door switch
-
D41G
Gate guard locking switch
-
D4NL
Guard-locking door switch in plastic housing
-
D41L
Hygienic guard locking switch
-
F3S-TGR-KHL_
Stainless steel guard-lock safety door switch
-
D4N
Limit switch with plastic housing
-
D4N-_R
Safety limit switch with manual reset
-
D4B-_N
Limit switch with metal housing
-
D4F
Safety limit switch in slim size housing
-
D4NH
Safety door hinge switch
-
D4NS
Key-operated door switch in plastic housing
-
D4GS
Key-operated door switch in slim housing
-
F3S-TGR-KM/KH
Safety door switches with stainless steel head or full stainless steel body
-
D4BS
Key-operated door switch in metal housing
-
F3S-TGR-N_R
Reed-type non contact door switch
-
F3S-TGR-N_X
Explosion proof non-contact switches
-
D40A
Non-contact door switch
-
D40Z
Non-contact door switch with integrated monitoring and self-diagnostics
-
F3S-TGR-N_C
Hall coded non-contact for monitoring the status of guarding doors
-
F3S-TGR-N_M/-N_U
RFID non-contact door switch
-
D41D
High-coded non-contact door switch
-
F3S-TGR-S_A/-S_D
Standalone non-contact door switch
-
D40ML
Compact non-contact door switch/flexible safety unit
Training courses
Get the training from our best engineers. Beginner to advanced level.
View training coursesSubscribe to product updates
Newsletters about product innovations, solutions and services, directly in your inbox.
Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
Download