J7TC
Thermal overload relay
Motor Protection from Overload and Phase -loss by Combination with J7KC for up to 2.2 kW (240 VAC) *, 5.5 kW (440 VAC)
- Push-In Plus wiring technology saves wiring and maintenance time
- One-touch installation with magnetic contactor J7KC to configure a magnetic starter
- High-reliability auxiliary circuit (2PST-1NO 1NC)
- Equipped with a dial cover as standard to suppress setting changes
- Easily switch between manual and automatic reset methods
- Certified as compliant with the main safety standards
Specifications & ordering info
Ordering Information
Main unit
Thermal overload relay
Settling current range | Order code |
---|---|
0.1-0.15 A | J7TC-01-E15 |
0.13-0.2 A | J7TC-01-E20 |
0.18-0.27 A | J7TC-01-E27 |
0.24-0.36 A | J7TC-01-E36 |
0.34-0.52 A | J7TC-01-E52 |
0.48-0.72 A | J7TC-01-E72 |
0.64-0.96 A | J7TC-01-E96 |
0.8-1.2 A | J7TC-01-1E2 |
0.95-1.45 A | J7TC-01-1E4 |
1.1-1.65 A | J7TC-01-1E6 |
1.4-2.1 A | J7TC-01-2E1 |
1.7-2.6 A | J7TC-01-2E6 |
2.2-3.4 A | J7TC-01-3E4 |
2.8-4.2 A | J7TC-01-4E2 |
4-6 A | J7TC-01-6 |
5-7.5 A | J7TC-01-7E5 |
6-9 A | J7TC-01-9 |
7-10.5 A | J7TC-01-10 |
9-13 A | J7TC-01-13 |
Accessories (Order Separately)
Insulation stop
Minimum order (bag) | Order code |
---|---|
1 (30 pcs./bag) |
J77KC-T (for main circuit) |
J77KC-K (for auxiliary circuit) |
Removal tool
Order code |
---|
J78KC |
Specifications
Main circuit rating |
Trip class | 10 A | ||||||||
3-pole load operation (At 20°C ambient temperature) IEC 60947-4-1/ JIS C 8201-4-1 |
Limit operation | No operation (cold start) | 105% (less than 2 hours)
2
Ratio to dial settling current. |
|||||||
Operation (hot start) | 120% (less than 2 hours)
2
Ratio to dial settling current. |
|||||||||
Operation when overload occurs (hot start) | 150% (less than 2 minutes)
2
Ratio to dial settling current. |
|||||||||
Operation when locking occurs (cold start) | 720% (over 2 s up to 10 s)
2
Ratio to dial settling current. |
|||||||||
2-pole load operation (At 20°C ambient temperature) IEC 60947-4-1/ JIS C 8201-4-1 |
Phase less protection device | With phase failure protection device | ||||||||
No operation (cold start) | 2 poles 100%/1 pole 90%
2
Ratio to dial settling current. |
|||||||||
Operation (hot start) | 2 poles 115%/1 pole 0% (less
than 2 hours)
2
Ratio to dial settling current. |
|||||||||
Ambient temperature compensation performance |
Ambient temperature 40°C |
No operation (cold start) | 100% (less than 2 hours)
2
Ratio to dial settling current. |
|||||||
Operation (hot start) | 120% (less than 2 hours)
2
Ratio to dial settling current. |
|||||||||
Ambient temperature –5°C |
No operation (cold start) | 105% (less than 2 hours)
2
Ratio to dial settling current. |
||||||||
Operation (hot start) | 130% (less than 2 hours)
2
Ratio to dial settling current. |
|||||||||
Auxiliary circuit rating |
Ratings based on IEC 60947-5-1 |
Rated voltage range (V) | 24 | 100-120 | 200-240 | 380-440 | 500-600 | |||
Rated operational current (A) |
AC-15 (Coil load) |
NC contact | 3.0 (0.5)
2
() indicates
the contact rating when set to auto release. |
2.5 (0.5)
2
() indicates
the contact rating when set to auto release. |
2.0 (0.5)
2
() indicates
the contact rating when set to auto release. |
1.0 (0.5)
2
() indicates
the contact rating when set to auto release. |
0.6 (0.5)
2
() indicates
the contact rating when set to auto release. |
|||
NO contact | 3.0 (0.5)
2
() indicates
the contact rating when set to auto release. |
2.5 (0.5)
2
() indicates
the contact rating when set to auto release. |
1.5 (0.5)
2
() indicates
the contact rating when set to auto release. |
0.75 (0.5)
2
() indicates
the contact rating when set to auto release. |
0.6 (0.5)
2
() indicates
the contact rating when set to auto release. |
|||||
DC-13 (Coil load) |
NC contact | 1.1 (0.3)
2
() indicates
the contact rating when set to auto release. |
0.28 | 0.14 | – | – | ||||
NO contact | 1.1 (0.3)
2
() indicates
the contact rating when set to auto release. |
0.28 | 0.14 | – | – | |||||
Conventional free air thermal current (Rated carry current) |
5 A | |||||||||
Ratings based on UL 508 |
Rated carry current (A) | 5 | 1 | |||||||
Rated voltage (V) | 120 AC | 240 AC | 480 AC | 600 AC | 125 DC | 250 DC | ||||
Contact closed current (A) | 30 | 15 | 7.5 | 6 | 0.22 | 0.11 | ||||
Breaking current (A) | 3 | 1.5 | 0.75 | 0.6 | 0.22 | 0.11 | ||||
Rating code | B600 | Q300 | ||||||||
Minimum operate voltage/current (reference value) | 5 VDC, 3 mA | |||||||||
Contact resistance (reference value) | 50 mΩ max. (6 VDC, 1 A, voltage drop method) | |||||||||
Contact structure | Single-break | |||||||||
Contact material | Ag alloy | |||||||||
Rated insulation voltage | 690VAC | |||||||||
Rated impulse dielectric strength | 6 kV | |||||||||
Rated frequency | 50/60 Hz | |||||||||
Vibration resistance | Vibration: 10 to 55 Hz, acceleration: 15m/s2 | |||||||||
Shock resistance | Shock value 50 m/s2 | |||||||||
Degree of protection | IP20 (IEC60529) | |||||||||
Operating temperature | −10 to +55°C (however, daily average shall not exceed 35°C) | |||||||||
Ambient storage temperature | −40 to +65°C (no condensation or icing) | |||||||||
Relative humidity | 45% to 85% RH (no condensation or icing) | |||||||||
Altitude | 2000 m max. | |||||||||
Weight | 110 g | |||||||||
Applicable standards | Safety standard | EN 60947-4-1 (IEC 60947-4-1), UL 60947-4-1, CSA 22.2 No.60947-4-1, CCC GB/T 14048.4 |
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Kontakta mig J7TC

Tack för din förfrågan. Vi återkommer inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
DownloadOffert för J7TC
Fyll i alla obligatoriska fält. Vänligen fyll i alla fält markerade med *. Dina personliga uppgifter behandlas konfidentiellt.

Tack för din offertförfrågan. Vi återkommer med önskad information inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
Download