F3S-TGR-N_C
Hall coded non-contact for monitoring the status of guarding doors
Hall coded non-contact switches monitor the status of guarding doors. Stainless steel housing for high hygiene demands in the food industry are available.
- Based on hall technology
- Connect up to 20 switches in series
- LED supports easy diagnosis
- Operates with all our safety controllers
- Operates behind stainless steel fittings
- Non-contact – no abrasion – no particles
- Compensation of mechanical tolerances
- Suitable for high pressure cleaning, CIP/SIP processes due IP69K (pre-wired types)
- Conforms to safety categories up PLe acc. EN ISO13849-1
Specifications & ordering info
Produkt | Door switch type | Guard-lock | Coding | Material housing | Ambient temperature (operating) | Door contacts NC | Door contacts NO | LED indicator | Connection method | Cable length | Cable exit direction | Degree of protection (IP) | Switch without actuator | Description | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 5 m | Left | IP69K | No | Non-contact door switch, coded, barrel plastic M30, 2NC+1NO, 5m cable |
|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 10 m | Left | IP69K | No | Non-contact door switch, coded, barrel plastic M30, 2NC+1NO, 10m cable |
|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 1 | Yes | M12 pigtail connector | 0.25 m | Left | IP67 | No | Non-contact door switch, coded, barrel plastic M30, 2NC+1NO, M12 connector pigtail |
|
|
Non-contact, Hall coded | No | Basic | Stainless steel | -25-105 °C | 2 | 1 | Yes | Cable | 5 m | Left | IP69K | No | Non-contact door switch, coded, elongated stainless steel, 2NC+1NO, 5m cable |
|
|
Non-contact, Hall coded | No | Basic | Stainless steel | -25-105 °C | 2 | 1 | Yes | Cable | 10 m | Left | IP69K | No | Non-contact door switch, coded, elongated stainless steel, 2NC+1NO, 10m cable |
|
|
Non-contact, Hall coded | No | Basic | Stainless steel | -25-105 °C | 2 | 1 | Yes | M12 pigtail connector | 0.25 m | Left | IP67 | No | Non-contact door switch, coded, elongated stainless steel, 2NC+1NO, M12 connector pigtail |
|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 0 | Yes | Cable | 2 m | Left | IP69K | No | Non-contact door switch, coded, elongated sensor 2 m, plastic, 2 NC contacts |
|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 0 | Yes | Cable | 5 m | Left | IP69K | No | Non-contact door switch, coded, elongated sensor 5m, plastic, 2 NC contacts |
|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 0 | Yes | Cable | 10 m | Left | IP69K | No | Non-contact door switch, coded, elongated sensor 10 m, plastic, 2 NC contacts |
|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 0 | Yes | M12 pigtail connector | 0.25 m | Left | IP67 | No | Non-contact door switch, coded, elongated sensor M12 connector, plastic, 2 NC contacts |
|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 2 m | Left | IP69K | No | Non-contact door switch, coded, elongated sensor 2m, plastic, 2 NC+1 NO contacts |
|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 5 m | Left | IP69K | No | Non-contact door switch, coded, elongated sensor plastic, 2 NC+1 NO, 5m cable |
|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 10 m | Left | IP69K | No | Non-contact door switch, coded, elongated sensor, plastic, 2 NC+1 NO contacts, 10m cable |
|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 1 | Yes | M12 pigtail connector | 0.25 m | Left | IP67 | No | Non-contact door switch, coded, elongated sensor, plastic, 2 NC+1 NO contacts, M12 connector pigtail |
|
|
Non-contact, Hall coded | No | Basic | Stainless steel, hygienic | -25-105 °C | 2 | 1 | Yes | Cable | 5 m | Left | IP69K | No | Non-contact door switch, coded, miniature stainless steel hygienic design, 2NC+1NO, 5m cable |
|
|
Non-contact, Hall coded | No | Basic | Stainless steel, hygienic | -25-105 °C | 2 | 1 | Yes | Cable | 10 m | Left | IP69K | No | Non-contact door switch, coded, miniature stainless steel hygienic design, 2NC+1NO, 10m cable |
|
|
Non-contact, Hall coded | No | Basic | Stainless steel, hygienic | -25-105 °C | 2 | 1 | Yes | M12 pigtail connector | 0.25 m | Left | IP67 | No | Non-contact door switch, coded, miniature stainless steel hygienic design, 2NC+1NO, M12 connector pigtail |
|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 0 | Yes | Cable | 2 m | Left | IP69K | No | Non-contact door switch, miniature, coded, 2m, plastic, 2 NC contacts |
|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 0 | Yes | Cable | 5 m | Left | IP69K | No | Non-contact door switch, miniature, coded, 5m,plastic, 2 NC contacts |
|
|
Non-contact, Hall coded | No | Basic | Polyester | -25-80 °C | 2 | 0 | Yes | Cable | 10 m | Left | IP69K | No | Non-contact door switch, miniature, coded, 10m, plastic, 2 NC contacts |
|
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Kontakta mig F3S-TGR-N_C
Tack för din förfrågan. Vi återkommer inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
DownloadOffert för F3S-TGR-N_C
Fyll i alla obligatoriska fält. Vänligen fyll i alla fält markerade med *. Dina personliga uppgifter behandlas konfidentiellt.
Tack för din offertförfrågan. Vi återkommer med önskad information inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
Download