D4BS

Funktioner

Nyckelbrytare av metall

Serie D4BS innehåller har två kontakter med 1NC/1NO eller 2NC i ett robust metallhölje. Typer med M12-kontaktdon och genomföringsöppningar, till exempel M20, finns också i sortimentet.

  • Robust metallhölje
  • Serie med två kontakter 1NC/1NO och 2NC
  • M20 kabelgenomföring eller M12-kontaktdon
  • Guldpläterade kontakter som standard ger hög tillförlitlighet.
  • Kan användas för standardbelastningar och mikrobelastningar
Tekniska data

Ordering information

Switches

Type

Mounting direction

Conduit size

Order code

1NC/1NO (slow-action)

2NC (slow-action)

1-conduit

Front-side mounting

Pg13.5

D4BS-15FS

D4BS-1AFS

Operation keys (order separately)

Type

Order code

Horizontal mounting

 

D4BS-K1

Vertical mounting

 

D4BS-K2

Adjustable mounting
(horizontal)

 

D4BS-K3

Specifications

Degree of protection1

IP67 (EN60947-5-1)

Durability2

Mechanical: 1,000,000 operations min.
Electrical: 500,000 operations min. (10 A at 250 VAC, resistive load)

Operating speed

0.1 m/s to 0.5 m/s

Operating frequency

30 operations/min max.

Rated frequency

50/60 Hz

Contact gap

2×2 mm min.

Direct opening force3

19.61 N min. (EN60947-5-1)

Direct opening travel3

20 mm min. (EN60947-5-1)

Full stroke

23 mm min.

Conventional enclosed thermal current (Ith)

20 A (EN60947-5-1)

Conditional short-circuit current

100 A (EN60947-5-1)

Pollution degree (operating environment)

3 (EN60947-5-1)

Protection against electric shock

Class I (with ground terminal)

Ambient temperature

Operating: -40 to 80°C (with no icing)

Note: The above values are initial values.

 


1. Although the switch box is protected from dust, oil, or water penetration, do not use the D4BS in places where dust, oil, water, or chemicals may penetrate through the key hole on the head, otherwise switch damage or malfunctioning may occur.

2. The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40 to 70%. Contact your Omron sales representative for more detailed information on other operating environments.

3. These figures are minimum requirements for safe operation.

1. Although the switch box is protected from dust, oil, or water penetration, do not use the D4BS in places where dust, oil, water, or chemicals may penetrate through the key hole on the head, otherwise switch damage or malfunctioning may occur.

2. The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40 to 70%. Contact your Omron sales representative for more detailed information on other operating environments.

3. These figures are minimum requirements for safe operation.

Prenumerera på produktuppdateringar

Nyhetsbrev om produktinnovationer, system och tjänster, direkt till din inkorg.

Tack för att du väljer att prenumerare på eNews. Du kommer inom kort att få ett e-postmeddelande från oss med en länk för att aktivera din prenumeration.

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download

Produktdokumentation

Hämta datablad, handböcker och broschyrer.

Sök i hämtningscentret

Kurser

Utbilda dig hos våra bästa tekniker. Från nybörjarnivå till avancerad nivå.

Visa kurser