M1
The Integrated Global Solution
System integration on EtherCAT® leads you to the stage where machine design is more flexible and higher efficiency, saving space, and integrated configuration by software tool
- IM and PM motor control in OLV & CLV (200% torque at 0Hz).
- Torque control for IM in OLV/CLV, PM in CLV.
- Speed, Position and Gear function.
- Flexible EtherCAT configuration: Standard and Ring topology.
- Built-in 1 encoder / pulse counter input.
- Safe Stop 0 (STO SIL3 PLe) wired and FSoE.
- Energy saving dedicated functionality.
- M1 STD built-in Modbus and M1 ECT built-in EtherCAT
- PC configuration tool: Sysmac Studio IDE
- Coated PCB for dust and moisture resistance.
- 10 years 24/7 Maintenance Free operation.
- CE,UKCA, cULus, KC, RCM and RoHS.
Specifications & ordering info
Produkt | Drive control method | Drive supply voltage | Max. motor output at constant torque | Max. motor output at variable torque | Built in EMC filter | Degree of protection (IP) | Compatible motor type | Communication port(s) | Finless type | Description | |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 0.2 kW | 0.4 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 0.2/0.4 kW (HD/ND), 1.6/2.0 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 0.2 kW | 0.4 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 0.2/0.4 kW (HD/ND), 1.6/2.0 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 0.4 kW | 0.75 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 0.4/0.75 kW (HD/ND), 3.0/3.5 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 0.4 kW | 0.75 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 0.4/0.75 kW (HD/ND), 3.0/3.5 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 0.75 kW | 1.1 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 0.75/1.1 kW (HD/ND), 5.0/6.0 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 0.75 kW | 1.1 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 0.75/1.1 kW (HD/ND), 5.0/6.0 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 1.5 kW | 2.2 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 1.5/2.2 kW (HD/ND), 8.0/9.6 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 1.5 kW | 2.2 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 1.5/2.2 kW (HD/ND), 8.0/9.6 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 2.2 kW | 3 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 2.2/3.0 kW (HD/ND), 11/12 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 2.2 kW | 3 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 2.2/3.0 kW (HD/ND), 11/12 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 3.7 kW | 5.5 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 3.7/5.5 kW (HD/ND), 17.5/19.6 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 3.7 kW | 5.5 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 3.7/5.5 kW (HD/ND), 17.5/19.6 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 5.5 kW | 7.5 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 5.5/7.5 kW (HD/ND), 25/30 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 5.5 kW | 7.5 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 5.5/7.5 kW (HD/ND), 25/30 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 5.5 kW | 7.5 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 5.5/7.5 kW (HD/ND), 25/30 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 7.5 kW | 11 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 7.5/11 kW (HD/ND), 33/40 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 7.5 kW | 11 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 7.5/11 kW (HD/ND), 33/40 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 11 kW | 15 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 11/15 kW (HD/ND), 47/56 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 11 kW | 15 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 11/15 kW (HD/ND), 47/56 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 15 kW | 18.5 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 15/18.5 kW (HD/ND), 60/69 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 15 kW | 18.5 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 15/18.5 kW (HD/ND), 60/69 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 18.5 kW | 22 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 18.5/22 kW (HD/ND), 76/88 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V three phase | 18.5 kW | 22 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 18.5/22 kW (HD/ND), 76/88 A (HD/ND), 200 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 0.4 kW | 0.75 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 0.4/0.75 kW (HD/ND), 1.8/2.1 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 0.4 kW | 0.75 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 0.4/0.75 kW (HD/ND), 1.8/2.1 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 0.7 kW | 1.1 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 0.7/1.1 kW (HD/ND), 3.4/4.1 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 0.7 kW | 1.1 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 0.7/1.1 kW (HD/ND), 3.4/4.1 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 1.5 kW | 2.2 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 1.5/2.2 kW (HD/ND), 4.8/5.5 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 1.5 kW | 2.2 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 1.5/2.2 kW (HD/ND), 4.8/5.5 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 2.2 kW | 3 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 2.2/3.0 kW (HD/ND), 5.5/6.9 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 2.2 kW | 3 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 2.2/3.0 kW (HD/ND), 5.5/6.9 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 3 kW | 4 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 3.0/4.0 kW (HD/ND), 7.2/8.8 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 3 kW | 4 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 3.0/4.0 kW (HD/ND), 7.2/8.8 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 4 kW | 5.5 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 4.0/5.5 kW (HD/ND), 9.2/11.1 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 4 kW | 5.5 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 4.0/5.5 kW (HD/ND), 9.2/11.1 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 5.5 kW | 7.5 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 5.5/7.5 kW (HD/ND), 14.8/17.5 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 5.5 kW | 7.5 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 5.5/7.5 kW (HD/ND), 14.8/17.5 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 7.5 kW | 11 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 7.5/11 kW (HD/ND), 18/23 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 7.5 kW | 11 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 7.5/11 kW (HD/ND), 18/23 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 11 kW | 15 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 11/15 kW (HD/ND), 24/31 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 11 kW | 15 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 11/15 kW (HD/ND), 24/31 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 15 kW | 18.5 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 15/18.5 kW (HD/ND), 31/38 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 15 kW | 18.5 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 15/18.5 kW (HD/ND), 31/38 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 18.5 kW | 22 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 18.5/22 kW (HD/ND), 39/45 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 18.5 kW | 22 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 18.5/22 kW (HD/ND), 39/45 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 22 kW | 30 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 22/30 kW (HD/ND), 45/60 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 400 V three phase | 22 kW | 30 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 22/30 kW (HD/ND), 45/60 A (HD/ND), 400 VAC, 3~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V single phase | 0.2 kW | 0.4 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 0.2/0.4 kW (HD/ND), 1.6/1.9 A (HD/ND), 200 VAC, 1~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V single phase | 0.2 kW | 0.4 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 0.2/0.4 kW (HD/ND), 1.6/1.9 A (HD/ND), 200 VAC, 1~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V single phase | 0.4 kW | 0.55 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 0.4/0.55 kW (HD/ND), 3.0/3.5 A (HD/ND), 200 VAC, 1~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V single phase | 0.4 kW | 0.55 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 0.4/0.55 kW (HD/ND), 3.0/3.5 A (HD/ND), 200 VAC, 1~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V single phase | 0.7 kW | 1.1 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 0.7/1.1 kW (HD/ND), 5.0/6.0 A (HD/ND), 200 VAC, 1~ input,OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V single phase | 0.7 kW | 1.1 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 0.7/1.1 kW (HD/ND), 5.0/6.0 A (HD/ND), 200 VAC, 1~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V single phase | 1.5 kW | 2.2 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 1.5/2.2 kW (HD/ND), 8.0/9.6 A (HD/ND), 200 VAC, 1~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V single phase | 1.5 kW | 2.2 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 1.5/2.2 kW (HD/ND), 8.0/9.6 A (HD/ND), 200 VAC, 1~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V single phase | 2.2 kW | 2.7 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 2.2/2.7 kW (HD/ND), 11/12 A (HD/ND), 200 VAC, 1~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V single phase | 2.2 kW | 2.7 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 2.2/2.7 kW (HD/ND), 11/12 A (HD/ND), 200 VAC, 1~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590 Hz. |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V single phase | 3.7 kW | 3.7 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | MODBUS Slave, Serial RS-485, USB | No | M1 AC Drive, 3.7 kW (HD), 17.5 A (HD), 200 VAC, 1~ input, OLV/CLV control, STO (wired), max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V single phase | 3.7 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 3.7kW (HD), 17.5 A (HD), 200 VAC, 1~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590Hz EtherCAT version. |
|
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector, V/f control, Vector control | 230 V single phase | 3.7 kW | No | IP20 | Induction or asynchronous motor, Permanent magnet motor | EtherCAT Slave, USB | No | M1 AC Drive, 3.7kW (HD), 17.5 A (HD), 200 VAC, 1~ input, OLV/CLV control, EtherCAT, STO (FSoE + wired), max. output freq. 590Hz EtherCAT version. |
|
Need assistance?
We’re here to help! Reach out, and our specialists will assist you in finding the best solution for your business.
Kontakta mig M1

Tack för din förfrågan. Vi återkommer inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
DownloadOffert för M1
Fyll i alla obligatoriska fält. Vänligen fyll i alla fält markerade med *. Dina personliga uppgifter behandlas konfidentiellt.

Tack för din offertförfrågan. Vi återkommer med önskad information inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
DownloadFeatures
Choices of motors
Safe and reliable manufacturing
Safe working environment
Safety always comes first. Omron's scalable safety solutions allow you to design machine safety according to customer needs. The M1 Series expands the flexibility of your safety solution
Reliable production
Modern production lines should be safe and reliable at the same time. Omron's integrated safety solution realizes a safe working environment for workers and high operational availability of each machine.
Motion and Drives
- STO (ISO 13849-1 Cat.3/PLe)
- FSoE
- Safety input (2CH) + EDM output