MX2
Born to Drive Machines
Specifically created for your application, the MX2 was developed to harmonise advanced motor and machine control. Thanks to its advanced design and algorithms, the MX2 provides smooth control down to zero speed, plus precise operation for cyclic operations and torque control capability in open loop.
- High starting torque: 200% at 0.5 Hz
- Torque control in open loop vector
- Double rating VT 120%/1 min and CT 150%/ 1 min
- IM & PM motor control
- Safety conforming to ISO13849-1 Category
- 3 performance level PLD
- Built-in Logic programming
- Positioning functionality
- Integrated at Omron machine Automation solution
- Fieldbus communications: EtherCAT, Modbus, DeviceNet, Profibus, CompoNet, MECHATROLINK-II and EtherNet/IP
- Ratings: 200 V single-phase from 0.1 to 2.2 kW, 200 V three-phase from 0.1 to 15.0 kW, 400 V three-phase from 0.4 to 15.0 kW.
Specifications & ordering info
Produkt | Drive control method | Drive supply voltage | Max. motor output at constant torque | Max. motor output at variable torque | Built in EMC filter | Degree of protection (IP) | Finless type | Compatible motor type | Regenerative solutions | Communication port(s) | Communication option(s) | Description | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Open loop V/f, Open loop vector | 230 V three phase | 0.1 kW | 0.2 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 0.1/0.2 kW (ND/LD), 1.0/1.2 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 0.2 kW | 0.4 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 0.2/0.4 kW (ND/LD), 1.6/1.9 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 0.4 kW | 0.55 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 0.4/0.55 kW (ND/LD), 3.0/3.5 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 0.75 kW | 1.1 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 0.75/1.1 kW (ND/LD), 5.0/6.0 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 1.5 kW | 2.2 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 1.5/2.2 kW (ND/LD), 8.0/9.6 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 2.2 kW | 3 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 2.2/ 3.0 kW (ND/LD), 11.0/12.0 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 4 kW | 5.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 3.7/5.5 kW (ND/LD), 17.5/19.6 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 5.5 kW | 7.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 5.5/7.5 kW (ND/LD), 25.0/30.0 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 7.5 kW | 11 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 7.5/11 kW (ND/LD), 33.0/40.0 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 11 kW | 15 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 11/15 kW (ND/LD), 47.0/56.0 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 15 kW | 18.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 15/18.5 kW (ND/LD), 60.0/69.0 A (ND/LD), 200 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 0.4 kW | 0.75 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 0.4/0.75 kW (ND/LD), 1.8/2.1 A (ND/LD), 400 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 0.4 kW | 0.75 kW | No | IP20 | Yes | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | 3G3MX2 inverter drive, 0.4/0.75 kW (HD/ND), 1.8/2.1 A (HD/ND), 400 VAC, 3~, sensorless vector, w/o heatsink, max. output freq. 580Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 0.75 kW | 1.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 0.75/1.5 kW (ND/LD), 3.4/4.1 A (ND/LD), 400 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 0.75 kW | 1.5 kW | No | IP20 | Yes | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | 3G3MX2 inverter drive, 0.75/1.5 kW (HD/ND), 3.4/4.1 A (HD/ND), 400 VAC, 3~, sensorless vector, w/o heatsink, max. output freq. 580Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 1.5 kW | 2.2 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 1.5/2.2 kW (ND/LD), 4.8/5.4 A (ND/LD), 400 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 1.5 kW | 2.2 kW | No | IP20 | Yes | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | 3G3MX2 inverter drive, 1.5/2.2 kW (HD/ND), 4.8/5.4 A (HD/ND), 400 VAC, 3~, sensorless vector, w/o heatsink, max. output freq. 580Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 2.2 kW | 3 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 2.2/3.0 kW (ND/LD), 5.5/6.9 A (ND/LD), 400 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 2.2 kW | 3 kW | No | IP20 | Yes | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | 3G3MX2 inverter drive, 2.2/3.0 kW (HD/ND), 5.5/6.9 A (HD/ND), 400 VAC, 3~, sensorless vector, w/o heatsink, max. output freq. 580Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 3 kW | 4 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-485, USB | CompoNet Slave, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, PROFIBUS DP Slave | MX2-EV2 inverter drive, 3.0/4.0 kW (ND/LD), 7.2/8.8 A (ND/LD), 400 VAC, 3~ input, sensorless vector, max. output freq. 590Hz |
|
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Kontakta mig MX2
Tack för din förfrågan. Vi återkommer inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
DownloadOffert för MX2
Fyll i alla obligatoriska fält. Vänligen fyll i alla fält markerade med *. Dina personliga uppgifter behandlas konfidentiellt.
Tack för din offertförfrågan. Vi återkommer med önskad information inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
DownloadTechnical support
Teknisk Support
Videos
Relaterade produkter
-
One software tool for inverters & servos
-
One software for your automation system
-
Winder / Unwinder dedicated functionality
-
Pump Sequencer dedicated functionality