CJ2 | Omron, Sverige

Login

Please use more than 6 characters. Forgot your password? Click here to reset.

Change password

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download

Register

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to content on this page

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download

Thank you for your interest

You now have access to CJ2

A confirmation email has been sent to

Continue to page

Please or get direct access to download this document

CJ2

Features

CJ2 PLC: High performances modular controller

Due to his high flexibility in configuration CJ2 is the ideal solution to be used in a wide range of machines in various application ranges from Packaging, Food and commodities to Digital and Automotive. Connectivity with most of the industrial communication networks in the market is a key factor to use CJ2 controller in all applications that need a data exchange between machines. Scalability between CJ2M and CJ2H CPU’s enables an exact match between functions required and HW to use to always provide a perfect ratio Price/Performance in each application. Robustness of the solution and proven quality complete the value of those products.

  • Always accessible through standard USB support
  • Standard Ethernet port with EtherNet/IP Data Link function
  • High program capacity from 5K steps up to 400K steps
  • Higher precision for machine operation and processing quality
  • Immediate refreshing of basic I/O ensures real-time processing
  • High data memory capacity of up to 832K words
  • Serial option board
  • Dedicated function block memory ensures efficient execution of function block software modules
Specifications & ordering info
Produkt Program capacity Data memory capacity Logic execution time Max. number of expansion units Max. number of local I/O points Communication port(s) Description
CPU, 50K steps program, 32K words data memory, 32K words x 4 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU with built-in EtherNet/IP port, 50K steps program, 32K words data memory, 32K words x 4 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU, 100K steps program, 32K words data memory, 32K words x 4 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU with built-in EtherNet/IP port, 100K steps program, 32K words data memory, 32K words x 4 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU, 150K steps program, 32K words data memory, 32K words x 10 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU with built-in EtherNet/IP port, 150K steps program, 32K words data memory, 32K words x 10 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU, 250K steps program, 32K words data memory, 32K words x 15 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU with built-in EtherNet/IP port, 250K steps program, 32K words data memory, 32K words x 15 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU, 400K steps program, 32K words data memory, 32K words x 25 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU with built-in EtherNet/IP port, 400K steps program, 32K words data memory, 32K words x 25 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU, 5K steps program, 32K words data memory, 32K words x 1 bank EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU, 10K steps program, 32K words data memory, 32K words x 1 bank EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU, 20K steps program, 32K words data memory, 32K words x 1 bank EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU, 30K steps program, 32K words data memory, 32K words x 4 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU, 60K steps program, 32K words data memory, 32K words x 4 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.
CPU with built-in EtherNet/IP port, 5K steps program, 32K words data memory, 32K words x 1 bank EM, 2560 I/O max, option port for RS-232C/485, USB programming port, 3 expansion racks max.
CPU with built-in EtherNet/IP port, 10K steps program, 32K words data memory, 32K words x 1 bank EM, 2560 I/O max, option port for RS-232C/485, USB programming port, 3 expansion racks max.
CPU with built-in EtherNet/IP port, 20K steps program, 32K words data memory, 32K words x 1 bank EM, 2560 I/O max, option port for RS-232C/485, USB programming port, 3 expansion racks max.
CPU with built-in EtherNet/IP port, 30K steps program, 32K words data memory, 32K words x 4 banks EM, 2560 I/O max, option port for RS-232C/485, USB programming port, 3 expansion racks max.
CPU with built-in EtherNet/IP port, 60K steps program, 32K words data memory, 32K words x 4 banks EM, 2560 I/O max, option port for RS-232C/485, USB programming port, 3 expansion racks max.
No results found. Please expand your filter selection.
Reset all filters
Compare products Show more products
Downloads

Anslutningsguide

download

CJ-series -[DeviceNet]- ABB IRC5 Robot Controller Anslutningsguide

en PDF 3 MB
o

Please or get direct access to download this document

download

CJ-series -[DeviceNet]- Janome Sewing Machine JR3000-series Desktop Robot Anslutningsguide

en PDF 2 MB
o

Please or get direct access to download this document

download

CJ-series -[EtherNet/IP]- ABB IRC5 Robot Controller Anslutningsguide

en PDF 6 MB
o

Please or get direct access to download this document

download

CJ-series -[EtherNet/IP]- Balluff BNI EIP-50x-105-Z015 Anslutningsguide

en PDF 3 MB
o

Please or get direct access to download this document

download

CJ-series -[EtherNet/IP]- DENSO WAVE RC8 Robot Controller Anslutningsguide

en PDF 4 MB
o

Please or get direct access to download this document

Show all anslutningsguide

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download

Product documentation

Download datasheets, manuals and brochures.

Browse download center

Training courses

Get the training from our best engineers. Beginner to advanced level.

View training courses