Login

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download

Register

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to content on this page

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download

Thank you for your interest

You now have access to Modern machine controller: OMRON NX I/O System

A confirmation email has been sent to

Continue to page

Please or get direct access to download this document

NX-serien

NX-serien

Performance and practicality for machine control

Modern machine control requires system-wide synchronisation of motion axes with microsecond accuracy. The NX I/O system offers this timing accuracy and repeatability for a wide variety of in- and outputs. Its ultra-fast internal bus system is synchronised with the Distributed Clock of the EtherCAT network, resulting in system-wide deterministic I/O operation.

  • Ideal match with Sysmac Machine automation controllers and CJ2-series PLC's
  • Synchronous I/O updates, system-wide, with less than 1 μs jitter using EtherCAT
  • High density: up to 16 digital or 8 analog signals in 12 mm width
  • Removable wiring terminals for easy system assembly and testing

Specifications & ordering info

Ordering information

Communication and control units

Module Type Protocol Connection Specification Width Order code
Communication coupler EtherCAT Slave 2 RJ45 ports
(in + out)
Up to 63 I/O units.
Max. 1,024 bytes in + 1,024 bytes out
Supports distributed clock
I/O power supply up to 10 A
46 mm NX-ECC203
EtherNet/IP Slave 2 RJ45 ports
with built-in switch
Up to 63 I/O units.
Max. 512 bytes in + 512 bytes out
Supports local safety communication
Free Run I/O refresh mode only
I/O power supply up to 10 A
NX-EIC202
2
The NX-EIC202 communication coupler unit does not support the NX-SL3500 safety controller unit.
Safety controller FSoE Protocol 128 Safety connections For up to 1,024 safety I/O points 30 mm NX-SL3500
32 Safety connections For up to 256 safety I/O points NX-SL3300

IO-Link master unit

Module Type No. of ports I/O refresh method Connection type
2
Units with Screwless push-in connections are supplied with the appropriate terminal connector.
Width Order code
IO-Link master 4 Free Run Screwless push-in (NX-TBA162) 12 mm NX-ILM400
Note:

For more detailed information about IO-Link master unit, refer to “IO-Link master datasheet (I191E-EN)”.

RFID units

Module Type No. of channels Amplifier/Antenna I/O refresh mode Connection type Width Order code
RFID unit 1 V680 series Free Run FG terminal block 30 mm NX-V680C1
2 NX-V680C2

Digital I/O units

Module type Channels, Signal type Performance
2
Digital I/O performance
Digital I/O performance Standard High Speed
ON delay OFF delay ON delay OFF delay
Input PNP 0.02 ms 0.4 ms 100 ns 100 ns
NPN
AC 10 ms 40 ms N.A. N.A.
Output PNP 0.5 ms 1.0 ms 300 ns 300 ns
, I/O Refresh Mode
Connection type
2
Units with screwless push-in connections are supplied with the appropriate terminal connector. Units with MIL/Fujitsu connectors are supplied without matching plugs.
Width Order code NPN-type
2
Order codes are for PNP-type signals (positive switching, 0 V common). Most models are also available as NPN-type (negative switching, 24 V common). Inputs of MIL-connector versions can be used as NPN or PNP.
AC Digital Input 4 inputs, 200 to 240 VAC, 50/60 Hz Free Run Screwless push-in (NX-TBA082) 12 mm NX-IA3117
Safety Digital Input 4 inputs + 2 test outputs Free Run Screwless push-in (NX-TBA082) 12 mm NX-SIH400
8 inputs + 2 test outputs Screwless push-in (NX-TBA162) NX-SID800
DC Digital Input 4 inputs, 3-wire connection High-speed Synchronous Time
Stamp
Screwless push-in (NX-TBA122) 12 mm NX-ID3444 NX-ID3344
High-speed Synchronous/Free Run NX-ID3443 NX-ID3343
Synchronous/Free Run NX-ID3417 NX-ID3317
8 inputs, 2-wire connection Screwless push-in (NX-TBA162) NX-ID4442 NX-ID4342
16 inputs, 1-wire connection NX-ID5442 NX-ID5342
1 × 20-pin MIL connector 30 mm NX-ID5142-5 same
M3 screw NX-ID5142-1 same
32 inputs, 1-wire connection 1 × 40-pin MIL connector NX-ID6142-5 same
1 × 40-pin Fujitsu connector NX-ID6142-6 same
DC Digital I/O 16 inputs + 16 outputs 0.5 A,
1-wire connection + common
Synchronous/Free Run 2 × 20-pin MIL connector 30 mm NX-MD6256-5 NX-MD6121-5
2 × 24-pin Fujitsu connector NX-MD6121-6
DC Digital Output 2 outputs 0.5 A, 3-wire connection High-speed Synchronous Time
Stamp
Screwless push-in (NX-TBA082) 12 mm NX-OD2258 NX-OD2154
4 outputs 0.5 A, 3-wire connection High-speed Synchronous/Free Run Screwless push-in (NX-TBA122) NX-OD3257 NX-OD3153
Synchronous/Free Run NX-OD3256 NX-OD3121
4 outputs 2 A/point, 8 A total, 3-wire connection Screwless push-in (NX-TBA162) NX-OD3268
8 outputs 0.5 A, 2-wire connection NX-OD4256 NX-OD4121
16 outputs 0.5 A, 1-wire connection NX-OD5256 NX-OD5121
1 × 20-pin MIL connector 30 mm NX-OD5256-5 NX-OD5121-5
M3 screw NX-OD5256-1 NX-OD5121-1
32 outputs 0.5 A, 1-wire connection 1 × 40-pin MIL connector NX-OD6256-5 NX-OD6121-5
1 × 40-pin Fujitsu connector NX-OD6121-6
Safety Digital Output 2 outputs, 2.0 A Free Run Screwless push-in (NX-TBA082) 12 mm NX-SOH200
4 outputs, 0.5 A NX-SOD400
Relay Digital Output 2 outputs, N.O., 2.0 A Free Run Screwless push-in (NX-TBA082) 12 mm NX-OC2633
8 outputs, N.O., 2.0 A 24 mm NX-OC4633
2 outputs, N.O.+ N.C., 2.0 A 12 mm NX-OC2733

Analog I/O units

Module type Signal type Performance, I/O Refresh Mode Channels Connection type
2
Units with screwless push-in connections are supplied with the appropriate terminal connector. Units with MIL/Fujitsu connectors are supplied without matching plugs.
Width Order code
Temperature Sensor
Input
Thermocouple type
B,E,J,K,L,N,R,S,T,U,WRe5-26,PLII
0.1°C resolution, 200 ms/unit
Free Run
2 Screwless push-in terminal block(s)
with cold junction sensor, calibrated
individually at the factory
12 mm NX-TS2101
4 24 mm NX-TS3101
0.01°C resolution, 10 ms/unit
Free Run
2 12 mm NX-TS2102
4 24 mm NX-TS3102
0.001°C resolution, 60 ms/unit
Free Run
2 12 mm NX-TS2104
4 24 mm NX-TS3104
RTD type
Pt100 (3-wire), Pt1000, Ni508.4
0.1°C resolution, 200 ms/unit
Free Run
2 Screwless push-in (NX-TBA162) 12 mm NX-TS2201
4 Screwless push-in
(NX-TBA162 + NX-TBB162)
24 mm NX-TS3201
0.01°C resolution, 10 ms/unit
Free Run
2 Screwless push-in (NX-TBA162) 12 mm NX-TS2202
4 Screwless push-in
(NX-TBA162 + NX-TBB162)
24 mm NX-TS3202
0.001°C resolution, 60 ms/unit
Free Run
2 Screwless push-in (NX-TBA162) 12 mm NX-TS2204
4 Screwless push-in
(NX-TBA162 + NX-TBB162)
24 mm NX-TS3204
Analog Input 4 to 20 mA
single ended
1/8000 resolution, 250 µs/channel
Free Run
2 Screwless push-in (NX-TBA082) 12 mm NX-AD2203
4 Screwless push-in (NX-TBA122) NX-AD3203
8 Screwless push-in (NX-TBA162) NX-AD4203
4 to 20 mA
differential
1/8000 resolution, 250 µs/channel
Free Run
2 Screwless push-in (NX-TBA082) NX-AD2204
4 Screwless push-in (NX-TBA122) NX-AD3204
8 Screwless push-in (NX-TBA162) NX-AD4204
1/30000 resolution,10 µs/channel
Synchronous/Free Run
2 Screwless push-in (NX-TBA082) NX-AD2208
4 Screwless push-in (NX-TBA122) NX-AD3208
8 Screwless push-in (NX-TBA162) NX-AD4208
–10 to 10 V
single ended
1/8000 resolution, 250 µs/channel
Free Run
2 Screwless push-in (NX-TBA082) NX-AD2603
4 Screwless push-in (NX-TBA122) NX-AD3603
8 Screwless push-in (NX-TBA162) NX-AD4603
–10 to 10 V
differential
1/8000 resolution, 250 µs/channel
Free Run
2 Screwless push-in (NX-TBA082) NX-AD2604
4 Screwless push-in (NX-TBA122) NX-AD3604
8 Screwless push-in (NX-TBA162) NX-AD4604
1/30000 resolution,10 µs/channel
Synchronous/Free Run
2 Screwless push-in (NX-TBA082) NX-AD2608
4 Screwless push-in (NX-TBA122) NX-AD3608
8 Screwless push-in (NX-TBA162) NX-AD4608
High-Speed Analog Input –10 to 10 V, –5 to 5 V, 0 to 10 V,
0 to 5 V, 1 to 5 V, 0 to 20 mA,
4 to 20 mA
differential
–10 to 10 V or –5 to 5 V: 1/64000
Other input range: 1/32000
5 µs/channel
Synchronous
4 (NPN) Screwless push-in
(NX-TBA162 + NX-TBB162)
24 mm NX-HAD401
4 (PNP) NX-HAD402
Analog Output 4 to 20 mA 1/8000 resolution, 250 µs/channel
Free Run
2 Screwless push-in (NX-TBA082) 12 mm NX-DA2203
4 Screwless push-in (NX-TBA122) NX-DA3203
1/30000 resolution,10 µs/channel
Synchronous/Free Run
2 Screwless push-in (NX-TBA082) NX-DA2205
4 Screwless push-in (NX-TBA122) NX-DA3205
–10 to 10 V 1/8000 resolution, 250 µs/channel
Free Run
2 Screwless push-in (NX-TBA082) NX-DA2603
4 Screwless push-in (NX-TBA122) NX-DA3603
1/30000 resolution,10 µs/channel
Synchronous/Free Run
2 Screwless push-in (NX-TBA082) NX-DA2605
4 Screwless push-in (NX-TBA122) NX-DA3605

Temperature control units

Module type Conversion time,
I/O Refresh Mode
Channels Input type Output type Output
capacity
CT Input
capacity
Control type Connection type Width Order code
Temperature
control
50 ms
Free run
2 Multi-input
(Thermo-
couple and
Resistance
thermometer)
Voltage output
(for driving
SSR)
2 points 2 points Standard Screwless push-in (NX-TBA162) 12 mm NX-TC2405
NX-TC2406
4 points Heating and
Cooling
NX-TC2407
Linear current
output
2 points Standard NX-TC2408
4 Voltage output
(for driving
SSR)
4 points 4 points Standard Screwless push-in
(NX-TBA162 + NX-TBB162)
24 mm NX-TC3405
NX-TC3406
8 points Heating and
Cooling
NX-TC3407
Linear current
output
4 points Standard NX-TC3408

Heater burnout detection units

Module type Channels, signal type Control output I/O refresh
method
Connection type
2
Units with screwless push-in connections are supplied with the appropriate terminal connector. Units with MIL/Fujitsu connectors are supplied without matching plugs.
Width Order code
Heater burnout detection 4 CT inputs
4 control outputs
NPN, 12 to 24 VDC
0.1 A/point, 0.4 A/unit
Free Run Screwless push-in (NX-TBA162) 12 mm NX-HB3101
PNP 24 VDC
0.1 A/point, 0.4 A/unit
NX-HB3201

Load cell input unit

Module type Specifications Excitation voltage/input range I/O refresh
method
Connection type
2
Units with screwless push-in connections are supplied with the appropriate terminal connector. Units with MIL/Fujitsu connectors are supplied without matching plugs.
Width Order code
Load cell input 1 load cell input, 125 µs conversion
cycle
5 VDC±10%/–5 to 5 mV/V Synchronous/
Free Run
Screwless push-in (NX-TBC162) 12 mm NX-RS1201

Position control units

Module type Channels, Signal type Performance, I/O Refresh Mode Connection type
2
Units with screwless push-in connections are supplied with the appropriate terminal connector. Units with MIL/Fujitsu connectors are supplied without matching plugs.
Width Order code NPN-type
2
Order codes are for PNP-type signals (positive switching, 0 V common). Most models are also available as NPN-type (negative switching, 24 V common). Inputs of MIL-connector versions can be used as NPN or PNP.
Encoder Input 1 SSI encoder, 2 MHz Synchronous/Free Run Screwless push-in (NX-TBA122) 12 mm NX-ECS112
2 SSI encoders, 2 MHz NX-ECS212
1 incremental encoder line driver
4 MHz + 3 Digital Inputs (1 µs)
Screwless push-in
(NX-TBA122 + NX-TBB122)
24 mm NX-EC0142 NX-EC0132
1 incremental encoder open collec-
tor 500 kHz + 3 Digital Inputs (1 µs)
Screwless push-in (NX-TBA162) 12 mm NX-EC0122 NX-EC0112
2 incremental encoders open collec-
tor 500 kHz
Screwless push-in (NX-TBA122) NX-EC0222 NX-EC0212
Pulse Output 1 Pulse Up/Down or Pulse/Direction
open collector 500 kHz + 2 Digital
Inputs + 1 Digital Output (1 µs)
Synchronous Screwless push-in (NX-TBA162) 12 mm NX-PG0122 NX-PG0112
2 pulse line driver 4 MHz + 5 digital
inputs per channel + 3 digital out-
puts per channel
1 × 34-pin MIL connector 30 mm NX-PG0242-5 NX-PG0232-5
4 pulse line driver 4 MHz + 5 digital
inputs per channel + 3 digital out-
puts per channel
2 × 34-pin MIL connector NX-PG0342-5 NX-PG0332-5

Serial communication interface units

Module type Channels, Signal type Performance, I/O Refresh Mode Connection type
2
Units with screwless push-in connections are supplied with the appropriate terminal connector. Units with MIL/Fujitsu connectors are supplied without matching plugs.
Width Order code NPN-type
2
Order codes are for PNP-type signals (positive switching, 0 V common). Most models are also available as NPN-type (negative switching, 24 V common). Inputs of MIL-connector versions can be used as NPN or PNP.
Serial Communication 1 × RS-422A/485 Free Run Screwless push-in (NX-TBC162) 12 mm NX-CIF105
1 × RS-232C NX-CIF101
2 × RS-232C 9-pin D-sub 30 mm NX-CIF210
Note:

Other units

Module type Description Connection type
2
Units with screwless push-in connections are supplied with the appropriate terminal connector.
Width Order code
Power Unit NX bus power supply unit, 24 V DC input, non-isolated Screwless push-in (NX-TBC082) 12 mm NX-PD1000
I/O power feed unit, for separation of power groups, up to 10 A Screwless push-in (NX-TBA082) NX-PF0730
I/O power connection unit, 16 × IOV Screwless push-in (NX-TBA162) NX-PC0020
I/O power connection unit, 16 × IOG NX-PC0010
I/O power connection, 8 × IOV + 8 x IOG NX-PC0030
System Units and
Accessories
Grounding terminal, 16 points Screwless push-in (NX-TBC162) NX-TBX01
End cover (included with Communication Coupler) NX-END01
Replacement front connector with 8 wiring terminals (marked A+B) Screwless push-in NX-TBA082
Replacement front connector with 12 wiring terminals (marked A+B) NX-TBA122
Replacement front connector with 16 wiring terminals (marked A+B) NX-TBA162
Replacement front connector with 12 wiring terminals (marked C+D) NX-TBB122
Replacement front connector with 16 wiring terminals (marked C+D) NX-TBB162
Replacement front connector with 8 wiring terminals (marked A+B+FG) NX-TBC082
Replacement front connector with 16 wiring terminals (marked A+B+FG) NX-TBC162
DIN rail insulation spacers, set of 3 pcs NX-AUX01
30 Unit pins + 30 Terminal keying pins, to prevent mismatch of unit and terminal block (one set is enough for 10 units) NX-AUX02

Accessories

Type Description Connection type Width Order code
End cover Included with communication coupler 12 mm NX-END01
Terminal block (replacement front connector) With 8 wiring terminals (A + B) Screwless push-in NX-TBA082
With 8 wiring terminals (A + B with FG) NX-TBC082
With 12 wiring terminals (A + B) NX-TBA122
With 12 wiring terminals (C + D) NX-TBB122
With 16 wiring terminals (A + B) NX-TBA162
With 16 wiring terminals (C + D) NX-TBB162
With 16 wiring terminals (A + B with FG) NX-TBC162
DIN rail insulation spacers Set of 3 pcs NX-AUX01
Terminal block coding pins For 10 units (Terminal block: 30 pins, unit: 30 pins) NX-AUX02
End plate To secure the units on the DIN track PFP-M

Accessories

Ethernet cables and accessories

EtherCAT patch cables, improved shield

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

20

30

50

100

150

200

300

500

750

1000

1500

2000

 

M12 straight

M12 straight

PVC

AWG22, 2 pairs

Black

XS5W-T421-[.]M2-SS

 

M12 straight

RJ45

PVC

AWG22, 2 pairs

Black

XS5W-T421-[.]MC-SS

Note: For [.] fill in the 1-character length code.

Ethernet patch cables, standard RJ45 connectors

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

20

30

50

100

150

200

300

500

750

1000

1500

2000

 

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Blue

XS6W-6LSZH8SS[...]CM-B

 

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Yellow

XS6W-6LSZH8SS[...]CM-Y

 

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Green

XS6W-6LSZH8SS[...]CM-G

 

RJ45 std.

RJ45 std.

PUR

Cat5e S/FTP 4 pairs

Green

XS6W-5PUR8SS[...]CM-G

Note: For [...] fill in the length in cm.

Ethernet patch cables, RJ45/M12 connectors

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

30

50

100

200

300

500

1000

1500

 

RJ45

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T421-[.]MD-K

 

M12 straight

M12 straight

PVC

Cat5e Shielded Quad

Light Blue

B

C

D

E

G

J

K

XS5W-T421-[.]M2-K

 

M12 straight

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T421-[.]MC-K

 

M12 angled

M12 angled

PVC

Cat5e Shielded Quad

Light Blue

B

C

D

E

G

J

K

XS5W-T422-[.]M2-K

 

M12 angled

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T422-[.]MC-K

Note: For [.] fill in the 1-character length code.

Specifications

Item

XS6W-6LSZH8SS_CM-_

XS6W-5PUR8SS_CM-G

Rated current

1 A (at 50°C)

Withstand voltage

1,000 VDC for 60 s (leakage current: 1 mA max.)

Ambient operating temperature

−20 to 60°C

−40 to 85°C

Ambient storage temperature

−20 to 60°C

−40 to 85°C

Ambient installation temperature

0 to 50°C

−10 to 60°C

Protective structure

IP20

IP20

Accessories

Ethernet cables and accessories

Accessories

Type

Connector

Specification

Color

Length

Order code

Ethernet installation cable

none

CAT 5, SF/UTP, 4 × 2 × AWG 24/1
(solid core), Polyurethane (PUR)

Green

100 m

WM IE-5IC4x2xAWG24/1-PUR

Ethernet installation cable

none

CAT 5, SF/UTP, 4 × 2 × AWG 26/7
(stranded core), Polyurethane (PUR)

100 m

WM IE-5CC4x2xAWG26/7-PUR

Ethernet socket

RJ45 socket

DIN-rail mount socket to terminate
installation cable in the cabinet

Grey

60 × 17.5 × 67 mm

WM IE-TO-RJ45-FJ-B

Ethernet field-mount plugs

Metal RJ45

for AWG22 to AWG26

Chrome

52 mm

WM IE-PS-RJ45-FH-BK

Ethernet field-mount plugs

Plastic RJ45

for AWG22 to AWG24

Black

52 mm

XS6G-T421-1

Industrial switching hubs

Shape

Functions

Ports

Failure detection

Power supply voltage

Order code

 

Quality of Service (QoS):

EtherNet/IP control data priority

Failure detection:

Broadcast storm and LSI error detection
10/100BASE-TX, Auto-negotiation

3

24.0 VDC±5%

W4S1-03B

 

5

W4S1-05B

W4S1-05C

EtherCAT junction slave

Shape

Functions

Ports

Power supply voltage

Order code

 

Creation of star- and tree topologies
in EtherCAT networks.

Distributed Clock (DC) is supported.

3

20.4 to 28.8 VDC

(24 VDC –15% to 20%)

GX-JC03

 

6

GX-JC06

 

How can we help you?

If you have a question or would like to ask for a quote, please contact us or send a request.

+46 (8) 632 35 00
Contact us

Kontakta mig NX-serien

nx prod

Vänligen fyll i alla fält markerade med *. Dina personliga uppgifter behandlas konfidentiellt.

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Text area error notification

Checkbox error notification

Checkbox error notification

Tack för din förfrågan. Vi återkommer inom kort.

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download
+46 (8) 632 35 00
+46 (8) 632 35 00
Request quotation
Request quotation

Offert för NX-serien

Fyll i alla obligatoriska fält. Vänligen fyll i alla fält markerade med *. Dina personliga uppgifter behandlas konfidentiellt.

nx prod

Personliga detaljer

NX-serien

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Offertinformation

Select notification error

Select notification error

Text area error notification

Checkbox error notification

Checkbox error notification

Tack för din offertförfrågan. Vi återkommer med önskad information inom kort.

Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.

Download
Request quotation
Request quotation

Features

Networks

ethercat-net-profinet 190x206px prod

We chose EtherCAT as control network for the Sysmac NJ Machine Controller series. The convenience of standard Ethernet cabling combined with extremely fast on-the-fly data exchange have resulted in a new machine control architecture. The resulting openness, modularity and determinism are the key elements in today's machine automation.

  • Using open standards for programming and networking assure exchangeability and interoperability with external systems
  • Modularity allows flexibility in system configurations for fast adaptation to end-user requirements
  • Determinism is needed to keep control of the machine while increasing performance and accuracy

EtherNet/IP uses the CIP protocol over standard Ethernet infrastructure to offer efficient yet reliable data exchange. Using the EtherNet/IP bus coupler, NX-series I/O - including safety control - can be connected to CJ/CS-series PLC's.

ProfiNet bus coupler expands NX I/O platform capabilities enabling a wider range of possible architectures.

Performance

synchronous io prod

Since each set of NX-series I/O's on an EtherCAT coupler counts as just a single EtherCAT node, the overall network performance is hardly affected by the number of installed I/O units. Keeping the number of EtherCAT nodes to a minimum will help to keep the refresh cycle times of EtherCAT motion axes as low as possible, even at high I/O counts. Furthermore, local fault or damage to an I/O unit will not affect other EtherCAT nodes down the line. The internal bus of the NX-series is fully synchronised with the EtherCAT Distributed Clock. This assures exact timing of any in- or output unit in the control system to within 1 µs, wherever the I/O units are mounted.

Design

push-in wiring prod

For the design of the NX-series, we used our experience in distributed I/O systems combined with customer feedback.

  • The units are compact, with a standard width of 12 mm per unit, yet offer up to 16 channels per unit
  • The front connectors feature toolless push-in wiring with 8 mm ferrules for wire up to 1.5 mm2
  • The terminals are removable to allow pre-wiring and safe step-by-step testing
  • Matching labels on unit and connector reduce the chance of incorrect assembly
  • You can insert 6 keys in the terminal and the unit to mechanically prevent a mismatch

Digital I/O Units

nx digital io prod

The NX-series let you mix economical standard I/O's with high-speed synchronous models. The standard digital I/O's have 16 connections per unit, with a choice of:

  • 3-wire sensor connection with power supply (4-channel units)
  • 2-wire contact inputs or actuator outputs (8-channel-units)
  • 1-wire connection for sensors and actuators already connected to a common power supply (16-channel units)

High-speed I/O's all use 3-wire connection, and have On/Off response times of less than 300 ns. Using the EtherCAT Distributed Clock, all inputs can be latched, and outputs can be controlled synchronously, with less than 1 µs jitter.

For even more control over the exact I/O timing, time-stamp inputs will tell you the exact time of each signal transition. Similarly, time-stamp outputs anywhere in the EtherCAT network can be independently controlled with sub-microsecond accuracy.

Analog I/O Units

nx analogue i o units prod

Input signals from analog sensors, 4-20 mA transmitters, thermocouples or resistance thermometers can easily be connected and used for monitoring, data logging, trending or PID control. Analog units are offered with sampling times down to 10 µs per channel and high resolution (1:30,000). Built-in filtering, offset correction, broken wire- and overrange detection are all standard functions. The user can select from 12 different thermocouple characteristics, °C/°F and indication resolution down to 0.01 degree. With up to eight inputs in just 12 mm width, the NX-series are among the most compact modules on the market today.

High-speed analog input unit

nx-had401 190x232 prod

The High-speed Analog Input Unit allows an up to 5µs sampling rate on analog signals. The fast measuring of analog signals enables an improved quality inspection or a vibration analysis for predictive maintenance. Machine’s Quality and Availability can be improved resulting then in a better OEE (Overall Equipment Effectiveness) rate. This unit can read up to 4 different signals at the same time by keeping the 5µs even if the 4 channels are used. The isolation between channels prevents from distortion between channels.

Position I/O Units

nx position i o units prod

Various types of encoder signals can be connected, from incremental to Synchronous Serial (SSI) encoders. The ability to synchronize the position data with the EtherCAT Distributed Clock means that the encoder can be used as a motion axis for gearing or following. Pulse outputs up to 500 kHz can be used for discrete control or positioning and can also be mapped as a motion axes when used with the Sysmac NJ machine controller.

IO-Link Master Unit

nxilm400 prod

IO-Link makes communication down to the sensor level visible

  • Machine downtime can be reduced.
  • Abnormality detection for shortest recovery.
  • Condition monitoring for predictive maintenance.
  • Individual identification for reduction of man hours.
  • NX I/O Series Master unit with screw-less terminal block or GX Series with IP67 protection class for watery and dusty environments.
  • Up to 4 sensors can be connected with one NX I/O Series IO-Link master unit.
  • Photoelectric and Proximity sensors available.

Integrated Safety

nx safety prod

Safety control units and safe in- and output units can be added to any NX-series EtherCAT I/O stations, to fully integrate safety and standard control in one network. The NX-series fulfills all safety Performance Levels from PL a to PL e. Since the standard NJ-series controllers (V1.06 and up) and NX-series bus couplers (V1.1 and up) can be used, standard control and safety can be scaled independently. 

More information

Temperature Control

nx in-panel tc prod

Optimize Control by Detecting Status Changes Easily Satisfy Both Productivity and Quality

  • Adaptive control for self-optimization of control setting due to process changes
  • Specialized function for better sealing application (packaging) and for water-cooled extruders (plastic)
  • Easier integration thanks to ProfiNet, Ethernet-IP and EtherCAT Fieldbus support
More information

Technical support

Teknisk Support

Våra tekniker hjälper dig att välja rätt produkt för din applikation, att komma igång med de produkter du köpt eller att hantera olika projektlösningar. Tack vare vår On-Line support "myOMRON" kan vi även erbjuda teknisk support dygnet runt, året runt. Välj själv hur du vill komma i kontakt med oss.
hotline icon

Relaterade produkter

  • GI S logo prod

    GI-S Series

  • NJ101-1000 alt01

    Sysmac controller – NJ1 Series

  • NJ501-1320

    Sysmac controller – NJ3 Series

  • NJ501-1320

    Sysmac controller – NJ5 Series

  • NX Safety Hybrid logo prod

    From single machine to production line all, safety interconnect

  • nx safety fsoe log0 prod

    Integrated safety into machine automation

  • NX1 prod

    Information & Productivity in a miniaturized size controller

  • nx1p2 cpu unit24 prod

    Compact in size, powerful in functionality

  • nx7 l prod

    Sysmac controller – NX7 series

  • nxr combined 400x400 prod

    Ethercat and Ethernet/IP IO Link masters and IO Hub IP67 remote terminals

  • ipc box panel prod

    IPC Machine Controller

  • sysmac studio prod

    Boost Your Productivity

Downloads

download
CJ-series -[EtherNet/IP]- NX-EIC + NX-ILM400 -[IO-Link]- Turck I/O Hub (TBIL) Anslutningsguide
en PDF 4 MB
o

Please or register to view this content

download
CJ-series -[EtherNet/IP]- NX-EIC + NX-ILM400 -[IO-Lnk]- MTS Sensors (E-Series) Anslutningsguide
en PDF 4 MB
o

Please or register to view this content

download
EAC Mark removal Meddelande om upphörande
enPDF 200 KB
download
High Speed Analog Test Library Användarmanual
enPDF 4 MB
download
CJ-series -[EtherNet/IP]- NX-EIC + NX-ILM400 -[IO-Link]- Turck I/O Hub (TBIL) Anslutningsguide
en PDF 4 MB
o

Please or register to view this content

download
CJ-series -[EtherNet/IP]- NX-EIC + NX-ILM400 -[IO-Lnk]- MTS Sensors (E-Series) Anslutningsguide
en PDF 4 MB
o

Please or register to view this content

download
NJ-series -[EtherCAT]- NX-ECC + NX-ILM400 -[IO-Link]- FESTO SFAW-series W Flow Sensor Anslutningsguide
en PDF 3 MB
o

Please or register to view this content

download
NJ-series -[EtherCAT]- NX-ECC + NX-ILM400 -[IO-Link]- FESTO SPAE- Pressure Sensor Anslutningsguide
en PDF 2 MB
o

Please or register to view this content