NX-serien
Performance and practicality for machine control
Modern machine control requires system-wide synchronisation of motion axes with microsecond accuracy. The NX I/O system offers this timing accuracy and repeatability for a wide variety of in- and outputs. Its ultra-fast internal bus system is synchronised with the Distributed Clock of the EtherCAT network, resulting in system-wide deterministic I/O operation.
- Ideal match with Sysmac Machine automation controllers and CJ2-series PLC's
- Synchronous I/O updates, system-wide, with less than 1 μs jitter using EtherCAT
- High density: up to 16 digital or 8 analog signals in 12 mm width
- Removable wiring terminals for easy system assembly and testing
Specifications & ordering info
Ordering information
Communication and control units
Module Type | Protocol | Connection | Specification | Width | Order code |
---|---|---|---|---|---|
Communication coupler | EtherCAT Slave | 2 RJ45 ports (in + out) |
Up to 63 I/O units. Max. 1,024 bytes in + 1,024 bytes out Supports distributed clock I/O power supply up to 10 A |
46 mm | NX-ECC203 |
EtherNet/IP Slave | 2 RJ45 ports with built-in switch |
Up to 63 I/O units. Max. 512 bytes in + 512 bytes out Supports local safety communication Free Run I/O refresh mode only I/O power supply up to 10 A |
NX-EIC202
2
The
NX-EIC202 communication coupler unit does not support the NX-SL3500
safety controller unit. |
||
Safety controller | FSoE Protocol | 128 Safety connections | For up to 1,024 safety I/O points | 30 mm | NX-SL3500 |
32 Safety connections | For up to 256 safety I/O points | NX-SL3300 |
IO-Link master unit
Module Type | No. of ports | I/O refresh method | Connection type
2
Units with Screwless push-in
connections are supplied with the appropriate terminal connector. |
Width | Order code |
---|---|---|---|---|---|
IO-Link master | 4 | Free Run | Screwless push-in (NX-TBA162) | 12 mm | NX-ILM400 |
For more detailed information about IO-Link master unit, refer to “IO-Link master datasheet (I191E-EN)”.
RFID units
Module Type | No. of channels | Amplifier/Antenna | I/O refresh mode | Connection type | Width | Order code |
---|---|---|---|---|---|---|
RFID unit | 1 | V680 series | Free Run | FG terminal block | 30 mm | NX-V680C1 |
2 | NX-V680C2 |
Digital I/O units
Module type | Channels, Signal type | Performance
2 ,
I/O Refresh ModeDigital I/O performance
|
Connection type
2
Units with screwless
push-in connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code | NPN-type
2
Order codes are for PNP-type signals
(positive switching, 0 V common). Most models are also available
as NPN-type (negative switching, 24 V common). Inputs of MIL-connector
versions can be used as NPN or PNP. |
||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AC Digital Input | 4 inputs, 200 to 240 VAC, 50/60 Hz | Free Run | Screwless push-in (NX-TBA082) | 12 mm | NX-IA3117 | – | ||||||||||||||||||||||||||||
Safety Digital Input | 4 inputs + 2 test outputs | Free Run | Screwless push-in (NX-TBA082) | 12 mm | NX-SIH400 | – | ||||||||||||||||||||||||||||
8 inputs + 2 test outputs | Screwless push-in (NX-TBA162) | NX-SID800 | – | |||||||||||||||||||||||||||||||
DC Digital Input | 4 inputs, 3-wire connection | High-speed Synchronous Time Stamp |
Screwless push-in (NX-TBA122) | 12 mm | NX-ID3444 | NX-ID3344 | ||||||||||||||||||||||||||||
High-speed Synchronous/Free Run | NX-ID3443 | NX-ID3343 | ||||||||||||||||||||||||||||||||
Synchronous/Free Run | NX-ID3417 | NX-ID3317 | ||||||||||||||||||||||||||||||||
8 inputs, 2-wire connection | Screwless push-in (NX-TBA162) | NX-ID4442 | NX-ID4342 | |||||||||||||||||||||||||||||||
16 inputs, 1-wire connection | NX-ID5442 | NX-ID5342 | ||||||||||||||||||||||||||||||||
1 × 20-pin MIL connector | 30 mm | NX-ID5142-5 | same | |||||||||||||||||||||||||||||||
M3 screw | NX-ID5142-1 | same | ||||||||||||||||||||||||||||||||
32 inputs, 1-wire connection | 1 × 40-pin MIL connector | NX-ID6142-5 | same | |||||||||||||||||||||||||||||||
1 × 40-pin Fujitsu connector | NX-ID6142-6 | same | ||||||||||||||||||||||||||||||||
DC Digital I/O | 16 inputs + 16 outputs 0.5 A, 1-wire connection + common |
Synchronous/Free Run | 2 × 20-pin MIL connector | 30 mm | NX-MD6256-5 | NX-MD6121-5 | ||||||||||||||||||||||||||||
2 × 24-pin Fujitsu connector | – | NX-MD6121-6 | ||||||||||||||||||||||||||||||||
DC Digital Output | 2 outputs 0.5 A, 3-wire connection | High-speed Synchronous Time Stamp |
Screwless push-in (NX-TBA082) | 12 mm | NX-OD2258 | NX-OD2154 | ||||||||||||||||||||||||||||
4 outputs 0.5 A, 3-wire connection | High-speed Synchronous/Free Run | Screwless push-in (NX-TBA122) | NX-OD3257 | NX-OD3153 | ||||||||||||||||||||||||||||||
Synchronous/Free Run | NX-OD3256 | NX-OD3121 | ||||||||||||||||||||||||||||||||
4 outputs 2 A/point, 8 A total, 3-wire connection | Screwless push-in (NX-TBA162) | NX-OD3268 | – | |||||||||||||||||||||||||||||||
8 outputs 0.5 A, 2-wire connection | NX-OD4256 | NX-OD4121 | ||||||||||||||||||||||||||||||||
16 outputs 0.5 A, 1-wire connection | NX-OD5256 | NX-OD5121 | ||||||||||||||||||||||||||||||||
1 × 20-pin MIL connector | 30 mm | NX-OD5256-5 | NX-OD5121-5 | |||||||||||||||||||||||||||||||
M3 screw | NX-OD5256-1 | NX-OD5121-1 | ||||||||||||||||||||||||||||||||
32 outputs 0.5 A, 1-wire connection | 1 × 40-pin MIL connector | NX-OD6256-5 | NX-OD6121-5 | |||||||||||||||||||||||||||||||
1 × 40-pin Fujitsu connector | – | NX-OD6121-6 | ||||||||||||||||||||||||||||||||
Safety Digital Output | 2 outputs, 2.0 A | Free Run | Screwless push-in (NX-TBA082) | 12 mm | NX-SOH200 | – | ||||||||||||||||||||||||||||
4 outputs, 0.5 A | NX-SOD400 | – | ||||||||||||||||||||||||||||||||
Relay Digital Output | 2 outputs, N.O., 2.0 A | Free Run | Screwless push-in (NX-TBA082) | 12 mm | NX-OC2633 | – | ||||||||||||||||||||||||||||
8 outputs, N.O., 2.0 A | 24 mm | NX-OC4633 | – | |||||||||||||||||||||||||||||||
2 outputs, N.O.+ N.C., 2.0 A | 12 mm | NX-OC2733 | – |
Analog I/O units
Module type | Signal type | Performance, I/O Refresh Mode | Channels | Connection type
2
Units with screwless
push-in connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code |
---|---|---|---|---|---|---|
Temperature Sensor Input |
Thermocouple type B,E,J,K,L,N,R,S,T,U,WRe5-26,PLII |
0.1°C resolution, 200 ms/unit Free Run |
2 | Screwless push-in terminal block(s) with cold junction sensor, calibrated individually at the factory |
12 mm | NX-TS2101 |
4 | 24 mm | NX-TS3101 | ||||
0.01°C resolution, 10 ms/unit Free Run |
2 | 12 mm | NX-TS2102 | |||
4 | 24 mm | NX-TS3102 | ||||
0.001°C resolution, 60 ms/unit Free Run |
2 | 12 mm | NX-TS2104 | |||
4 | 24 mm | NX-TS3104 | ||||
RTD type Pt100 (3-wire), Pt1000, Ni508.4 |
0.1°C resolution, 200 ms/unit Free Run |
2 | Screwless push-in (NX-TBA162) | 12 mm | NX-TS2201 | |
4 | Screwless push-in (NX-TBA162 + NX-TBB162) |
24 mm | NX-TS3201 | |||
0.01°C resolution, 10 ms/unit Free Run |
2 | Screwless push-in (NX-TBA162) | 12 mm | NX-TS2202 | ||
4 | Screwless push-in (NX-TBA162 + NX-TBB162) |
24 mm | NX-TS3202 | |||
0.001°C resolution, 60 ms/unit Free Run |
2 | Screwless push-in (NX-TBA162) | 12 mm | NX-TS2204 | ||
4 | Screwless push-in (NX-TBA162 + NX-TBB162) |
24 mm | NX-TS3204 | |||
Analog Input | 4 to 20 mA single ended |
1/8000 resolution, 250 µs/channel Free Run |
2 | Screwless push-in (NX-TBA082) | 12 mm | NX-AD2203 |
4 | Screwless push-in (NX-TBA122) | NX-AD3203 | ||||
8 | Screwless push-in (NX-TBA162) | NX-AD4203 | ||||
4 to 20 mA differential |
1/8000 resolution, 250 µs/channel Free Run |
2 | Screwless push-in (NX-TBA082) | NX-AD2204 | ||
4 | Screwless push-in (NX-TBA122) | NX-AD3204 | ||||
8 | Screwless push-in (NX-TBA162) | NX-AD4204 | ||||
1/30000 resolution,10 µs/channel Synchronous/Free Run |
2 | Screwless push-in (NX-TBA082) | NX-AD2208 | |||
4 | Screwless push-in (NX-TBA122) | NX-AD3208 | ||||
8 | Screwless push-in (NX-TBA162) | NX-AD4208 | ||||
–10 to 10 V single ended |
1/8000 resolution, 250 µs/channel Free Run |
2 | Screwless push-in (NX-TBA082) | NX-AD2603 | ||
4 | Screwless push-in (NX-TBA122) | NX-AD3603 | ||||
8 | Screwless push-in (NX-TBA162) | NX-AD4603 | ||||
–10 to 10 V differential |
1/8000 resolution, 250 µs/channel Free Run |
2 | Screwless push-in (NX-TBA082) | NX-AD2604 | ||
4 | Screwless push-in (NX-TBA122) | NX-AD3604 | ||||
8 | Screwless push-in (NX-TBA162) | NX-AD4604 | ||||
1/30000 resolution,10 µs/channel Synchronous/Free Run |
2 | Screwless push-in (NX-TBA082) | NX-AD2608 | |||
4 | Screwless push-in (NX-TBA122) | NX-AD3608 | ||||
8 | Screwless push-in (NX-TBA162) | NX-AD4608 | ||||
High-Speed Analog Input | –10 to 10 V, –5 to 5 V, 0 to 10 V, 0 to 5 V, 1 to 5 V, 0 to 20 mA, 4 to 20 mA differential |
–10 to 10 V or –5 to 5 V: 1/64000 Other input range: 1/32000 5 µs/channel Synchronous |
4 (NPN) | Screwless push-in (NX-TBA162 + NX-TBB162) |
24 mm | NX-HAD401 |
4 (PNP) | NX-HAD402 | |||||
Analog Output | 4 to 20 mA | 1/8000 resolution, 250 µs/channel Free Run |
2 | Screwless push-in (NX-TBA082) | 12 mm | NX-DA2203 |
4 | Screwless push-in (NX-TBA122) | NX-DA3203 | ||||
1/30000 resolution,10 µs/channel Synchronous/Free Run |
2 | Screwless push-in (NX-TBA082) | NX-DA2205 | |||
4 | Screwless push-in (NX-TBA122) | NX-DA3205 | ||||
–10 to 10 V | 1/8000 resolution, 250 µs/channel Free Run |
2 | Screwless push-in (NX-TBA082) | NX-DA2603 | ||
4 | Screwless push-in (NX-TBA122) | NX-DA3603 | ||||
1/30000 resolution,10 µs/channel Synchronous/Free Run |
2 | Screwless push-in (NX-TBA082) | NX-DA2605 | |||
4 | Screwless push-in (NX-TBA122) | NX-DA3605 |
Temperature control units
Module type | Conversion time, I/O Refresh Mode |
Channels | Input type | Output type | Output capacity |
CT Input capacity |
Control type | Connection type | Width | Order code |
---|---|---|---|---|---|---|---|---|---|---|
Temperature control |
50 ms Free run |
2 | Multi-input (Thermo- couple and Resistance thermometer) |
Voltage output (for driving SSR) |
2 points | 2 points | Standard | Screwless push-in (NX-TBA162) | 12 mm | NX-TC2405 |
– | NX-TC2406 | |||||||||
4 points | Heating and Cooling |
NX-TC2407 | ||||||||
Linear current output |
2 points | Standard | NX-TC2408 | |||||||
4 | Voltage output (for driving SSR) |
4 points | 4 points | Standard | Screwless push-in (NX-TBA162 + NX-TBB162) |
24 mm | NX-TC3405 | |||
– | NX-TC3406 | |||||||||
8 points | Heating and Cooling |
NX-TC3407 | ||||||||
Linear current output |
4 points | Standard | NX-TC3408 |
Heater burnout detection units
Module type | Channels, signal type | Control output | I/O refresh method |
Connection type
2
Units with screwless
push-in connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code |
---|---|---|---|---|---|---|
Heater burnout detection | 4 CT inputs 4 control outputs |
NPN, 12 to 24 VDC 0.1 A/point, 0.4 A/unit |
Free Run | Screwless push-in (NX-TBA162) | 12 mm | NX-HB3101 |
PNP 24 VDC 0.1 A/point, 0.4 A/unit |
NX-HB3201 |
Load cell input unit
Module type | Specifications | Excitation voltage/input range | I/O refresh method |
Connection type
2
Units with screwless
push-in connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code |
---|---|---|---|---|---|---|
Load cell input | 1 load cell input, 125 µs conversion cycle |
5 VDC±10%/–5 to 5 mV/V | Synchronous/ Free Run |
Screwless push-in (NX-TBC162) | 12 mm | NX-RS1201 |
Position control units
Module type | Channels, Signal type | Performance, I/O Refresh Mode | Connection type
2
Units with screwless
push-in connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code | NPN-type
2
Order codes are for PNP-type signals
(positive switching, 0 V common). Most models are also available
as NPN-type (negative switching, 24 V common). Inputs of MIL-connector
versions can be used as NPN or PNP. |
---|---|---|---|---|---|---|
Encoder Input | 1 SSI encoder, 2 MHz | Synchronous/Free Run | Screwless push-in (NX-TBA122) | 12 mm | NX-ECS112 | – |
2 SSI encoders, 2 MHz | NX-ECS212 | – | ||||
1 incremental encoder line driver 4 MHz + 3 Digital Inputs (1 µs) |
Screwless push-in (NX-TBA122 + NX-TBB122) |
24 mm | NX-EC0142 | NX-EC0132 | ||
1 incremental encoder open collec- tor 500 kHz + 3 Digital Inputs (1 µs) |
Screwless push-in (NX-TBA162) | 12 mm | NX-EC0122 | NX-EC0112 | ||
2 incremental encoders open collec- tor 500 kHz |
Screwless push-in (NX-TBA122) | NX-EC0222 | NX-EC0212 | |||
Pulse Output | 1 Pulse Up/Down or Pulse/Direction open collector 500 kHz + 2 Digital Inputs + 1 Digital Output (1 µs) |
Synchronous | Screwless push-in (NX-TBA162) | 12 mm | NX-PG0122 | NX-PG0112 |
2 pulse line driver 4 MHz + 5 digital inputs per channel + 3 digital out- puts per channel |
1 × 34-pin MIL connector | 30 mm | NX-PG0242-5 | NX-PG0232-5 | ||
4 pulse line driver 4 MHz + 5 digital inputs per channel + 3 digital out- puts per channel |
2 × 34-pin MIL connector | NX-PG0342-5 | NX-PG0332-5 |
Serial communication interface units
Module type | Channels, Signal type | Performance, I/O Refresh Mode | Connection type
2
Units with screwless
push-in connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code | NPN-type
2
Order codes are for PNP-type signals
(positive switching, 0 V common). Most models are also available
as NPN-type (negative switching, 24 V common). Inputs of MIL-connector
versions can be used as NPN or PNP. |
---|---|---|---|---|---|---|
Serial Communication | 1 × RS-422A/485 | Free Run | Screwless push-in (NX-TBC162) | 12 mm | NX-CIF105 | – |
1 × RS-232C | NX-CIF101 | – | ||||
2 × RS-232C | 9-pin D-sub | 30 mm | NX-CIF210 | – |
Other units
Module type | Description | Connection type
2
Units with screwless push-in
connections are supplied with the appropriate terminal connector. |
Width | Order code |
---|---|---|---|---|
Power Unit | NX bus power supply unit, 24 V DC input, non-isolated | Screwless push-in (NX-TBC082) | 12 mm | NX-PD1000 |
I/O power feed unit, for separation of power groups, up to 10 A | Screwless push-in (NX-TBA082) | NX-PF0730 | ||
I/O power connection unit, 16 × IOV | Screwless push-in (NX-TBA162) | NX-PC0020 | ||
I/O power connection unit, 16 × IOG | NX-PC0010 | |||
I/O power connection, 8 × IOV + 8 x IOG | NX-PC0030 | |||
System Units and Accessories |
Grounding terminal, 16 points | Screwless push-in (NX-TBC162) | NX-TBX01 | |
End cover (included with Communication Coupler) | – | NX-END01 | ||
Replacement front connector with 8 wiring terminals (marked A+B) | Screwless push-in | NX-TBA082 | ||
Replacement front connector with 12 wiring terminals (marked A+B) | NX-TBA122 | |||
Replacement front connector with 16 wiring terminals (marked A+B) | NX-TBA162 | |||
Replacement front connector with 12 wiring terminals (marked C+D) | NX-TBB122 | |||
Replacement front connector with 16 wiring terminals (marked C+D) | NX-TBB162 | |||
Replacement front connector with 8 wiring terminals (marked A+B+FG) | NX-TBC082 | |||
Replacement front connector with 16 wiring terminals (marked A+B+FG) | NX-TBC162 | |||
DIN rail insulation spacers, set of 3 pcs | – | NX-AUX01 | ||
30 Unit pins + 30 Terminal keying pins, to prevent mismatch of unit and terminal block (one set is enough for 10 units) | – | NX-AUX02 |
Accessories
Type | Description | Connection type | Width | Order code |
---|---|---|---|---|
End cover | Included with communication coupler | – | 12 mm | NX-END01 |
Terminal block (replacement front connector) | With 8 wiring terminals (A + B) | Screwless push-in | NX-TBA082 | |
With 8 wiring terminals (A + B with FG) | NX-TBC082 | |||
With 12 wiring terminals (A + B) | NX-TBA122 | |||
With 12 wiring terminals (C + D) | NX-TBB122 | |||
With 16 wiring terminals (A + B) | NX-TBA162 | |||
With 16 wiring terminals (C + D) | NX-TBB162 | |||
With 16 wiring terminals (A + B with FG) | NX-TBC162 | |||
DIN rail insulation spacers | Set of 3 pcs | – | – | NX-AUX01 |
Terminal block coding pins | For 10 units (Terminal block: 30 pins, unit: 30 pins) | NX-AUX02 | ||
End plate | To secure the units on the DIN track | PFP-M |
Accessories
Ethernet cables and accessories
EtherCAT patch cables, improved shield
Note: For [.] fill in the 1-character length code.
Ethernet patch cables, standard RJ45 connectors
Note: For [...] fill in the length in cm.
Ethernet patch cables, RJ45/M12 connectors
Note: For [.] fill in the 1-character length code.
Specifications
Accessories
Ethernet cables and accessories
Accessories
Industrial switching hubs
EtherNet/IP control data priority
Broadcast storm and LSI error detection |
|||||
EtherCAT junction slave
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Kontakta mig NX-serien
Tack för din förfrågan. Vi återkommer inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
DownloadOffert för NX-serien
Fyll i alla obligatoriska fält. Vänligen fyll i alla fält markerade med *. Dina personliga uppgifter behandlas konfidentiellt.
Tack för din offertförfrågan. Vi återkommer med önskad information inom kort.
Vi har tekniska problem. Din formulär har inte varit framgångsrik. Vi ber om ursäkt och försök igen senare.
DownloadFeatures
Networks
We chose EtherCAT as control network for the Sysmac NJ Machine Controller series. The convenience of standard Ethernet cabling combined with extremely fast on-the-fly data exchange have resulted in a new machine control architecture. The resulting openness, modularity and determinism are the key elements in today's machine automation.
- Using open standards for programming and networking assure exchangeability and interoperability with external systems
- Modularity allows flexibility in system configurations for fast adaptation to end-user requirements
- Determinism is needed to keep control of the machine while increasing performance and accuracy
EtherNet/IP uses the CIP protocol over standard Ethernet infrastructure to offer efficient yet reliable data exchange. Using the EtherNet/IP bus coupler, NX-series I/O - including safety control - can be connected to CJ/CS-series PLC's.
ProfiNet bus coupler expands NX I/O platform capabilities enabling a wider range of possible architectures.
Performance
Since each set of NX-series I/O's on an EtherCAT coupler counts as just a single EtherCAT node, the overall network performance is hardly affected by the number of installed I/O units. Keeping the number of EtherCAT nodes to a minimum will help to keep the refresh cycle times of EtherCAT motion axes as low as possible, even at high I/O counts. Furthermore, local fault or damage to an I/O unit will not affect other EtherCAT nodes down the line. The internal bus of the NX-series is fully synchronised with the EtherCAT Distributed Clock. This assures exact timing of any in- or output unit in the control system to within 1 µs, wherever the I/O units are mounted.
Design
For the design of the NX-series, we used our experience in distributed I/O systems combined with customer feedback.
- The units are compact, with a standard width of 12 mm per unit, yet offer up to 16 channels per unit
- The front connectors feature toolless push-in wiring with 8 mm ferrules for wire up to 1.5 mm2
- The terminals are removable to allow pre-wiring and safe step-by-step testing
- Matching labels on unit and connector reduce the chance of incorrect assembly
- You can insert 6 keys in the terminal and the unit to mechanically prevent a mismatch
Digital I/O Units
The NX-series let you mix economical standard I/O's with high-speed synchronous models. The standard digital I/O's have 16 connections per unit, with a choice of:
- 3-wire sensor connection with power supply (4-channel units)
- 2-wire contact inputs or actuator outputs (8-channel-units)
- 1-wire connection for sensors and actuators already connected to a common power supply (16-channel units)
High-speed I/O's all use 3-wire connection, and have On/Off response times of less than 300 ns. Using the EtherCAT Distributed Clock, all inputs can be latched, and outputs can be controlled synchronously, with less than 1 µs jitter.
For even more control over the exact I/O timing, time-stamp inputs will tell you the exact time of each signal transition. Similarly, time-stamp outputs anywhere in the EtherCAT network can be independently controlled with sub-microsecond accuracy.
Analog I/O Units
Input signals from analog sensors, 4-20 mA transmitters, thermocouples or resistance thermometers can easily be connected and used for monitoring, data logging, trending or PID control. Analog units are offered with sampling times down to 10 µs per channel and high resolution (1:30,000). Built-in filtering, offset correction, broken wire- and overrange detection are all standard functions. The user can select from 12 different thermocouple characteristics, °C/°F and indication resolution down to 0.01 degree. With up to eight inputs in just 12 mm width, the NX-series are among the most compact modules on the market today.
High-speed analog input unit
The High-speed Analog Input Unit allows an up to 5µs sampling rate on analog signals. The fast measuring of analog signals enables an improved quality inspection or a vibration analysis for predictive maintenance. Machine’s Quality and Availability can be improved resulting then in a better OEE (Overall Equipment Effectiveness) rate. This unit can read up to 4 different signals at the same time by keeping the 5µs even if the 4 channels are used. The isolation between channels prevents from distortion between channels.
Position I/O Units
Various types of encoder signals can be connected, from incremental to Synchronous Serial (SSI) encoders. The ability to synchronize the position data with the EtherCAT Distributed Clock means that the encoder can be used as a motion axis for gearing or following. Pulse outputs up to 500 kHz can be used for discrete control or positioning and can also be mapped as a motion axes when used with the Sysmac NJ machine controller.
IO-Link Master Unit
IO-Link makes communication down to the sensor level visible
- Machine downtime can be reduced.
- Abnormality detection for shortest recovery.
- Condition monitoring for predictive maintenance.
- Individual identification for reduction of man hours.
- NX I/O Series Master unit with screw-less terminal block or GX Series with IP67 protection class for watery and dusty environments.
- Up to 4 sensors can be connected with one NX I/O Series IO-Link master unit.
- Photoelectric and Proximity sensors available.
Integrated Safety
Safety control units and safe in- and output units can be added to any NX-series EtherCAT I/O stations, to fully integrate safety and standard control in one network. The NX-series fulfills all safety Performance Levels from PL a to PL e. Since the standard NJ-series controllers (V1.06 and up) and NX-series bus couplers (V1.1 and up) can be used, standard control and safety can be scaled independently.
Temperature Control
Optimize Control by Detecting Status Changes Easily Satisfy Both Productivity and Quality
- Adaptive control for self-optimization of control setting due to process changes
- Specialized function for better sealing application (packaging) and for water-cooled extruders (plastic)
- Easier integration thanks to ProfiNet, Ethernet-IP and EtherCAT Fieldbus support
Technical support
Teknisk Support
Relaterade produkter
-
GI-S Series
-
Sysmac controller – NJ1 Series
-
Sysmac controller – NJ3 Series
-
Sysmac controller – NJ5 Series
-
From single machine to production line all, safety interconnect
-
Integrated safety into machine automation
-
Information & Productivity in a miniaturized size controller
-
Compact in size, powerful in functionality
-
Sysmac controller – NX7 series
-
Ethercat and Ethernet/IP IO Link masters and IO Hub IP67 remote terminals
-
IPC Machine Controller
-
Boost Your Productivity